7361229 REPL PWA SEARS 300

Installation Guide & Owners Manual Electronic Control Board PWA Replacement Kenmore 38300

For 7361229.

PDF File Manual, 1 pages, Read Online | Download pdf file

7361229 photo
hold for immediate
Low Salt
Select
press for tonight
ELECTRONIC CONTROL BOARD (PWA) REPLACEMENT
7361237 (Rev. A 11/29/16)
Position markers
(valve in service)
CAM
MOTOR
Figure 1
Figure 3
UP button
SELECT
button
DOWN
button
Display
REGENERATION
button
1. Unplug the water softener’s power supply.
2. Remove the water softener’s salt lid and top cover to expose
the valve.
3. Unplug the wiring connections from the back of the old
Electronic Control Board (See Figure 2).
4. Carefully remove the old board by unsnapping it from its
retainer tabs.
5. Carefully snap the new Electronic Control Board into the
retainer tabs.
6. Reconnect the wiring to the new board (See Fig. 2).
7. Plug the power supply into the electrical outlet. A number
shows in the display for a few seconds, followed by a flashing
“- - - -“.
NOTE: If “- - - -” is not flashing in the display, press and hold the
SELECT button until a model code appears.
8. Use the r UP or s DOWN buttons to select the correct
model code for your softener (see table below).
IM
PORTANT: BE SURE THE VALVE CAM INDICATES
``SERVICE'' POSITION (See Figure 1) WHEN REPLACING THE
ELECTRONIC CONTROL BOARD (PWA), TO ASSURE BOTH
VALVE AND PWA ARE ORIENTED, OR TIMED, TO THE SAME
CYCLE. If the valve is not in Service position, see step 13 below.
NOTE: When installing the electronic control board (PWA) on the face-
plate, use care not to twist the circuit board, or force it onto the
mounting pegs. Twisting could damage the printed circuits, or break the
display glass.
9. With the correct model code displayed, press the SELECT
button. The electronic controller will restart, briefly displaying
the model code you set.
10. Press the r UP or s DOWN buttons to set the present time.
Up moves the display ahead; down sets the time back. Be
sure AM or PM is correct.
11. Press the SELECT button a few times, until the time appears
on the display, but is not flashing.
12. For information about programming additional features of the
softener, consult your owners manual.
13. If the valve is not in Service position, press the REGENERA-
TION button and hold for 3 seconds to start a recharge cycle.
The display will flash “RECHARGE NOW.” In about 2 hours
the recharge cycle will be complete and the valve and elec-
tronic control board will be properly oriented together.
NOTE: To save time, use the manual advance procedures to
properly time and check operation. See service informa-
tion in the manual.
If you have questions about installation, call the
Kenmore Water Line at 1-800-426-9345.
Softener
Model
Serial Number begins with
(see rating decal inside unit)
Model Code
to select
625.383000 3830001 300
625.383001 3830017 301
Figure 2
Power
Supply
to Valve
Position Switch
to Valve
Motor
Back of Electronic
Control Board
to Turbine
Switch

Other documents for EcoPure 7361229

The following documents are available:
User Manual
  • Installation Guide & Owners Manual Electronic Control Board PWA Replacement Kenmore 38300 - (English) Read Online | Download pdf
Photos

Specifications