Additional spacing of 1" (2.5 cm) on all sides of the dryer is
recommended to reduce noise transfer.
For closet installation with a door, minimum ventilation
openings in the top and bottom of the door are required.
Louvered doors with equivalent ventilation openings are
acceptable.
Companion appliance spacing should also be considered.
Recessed or closet installation - Dryer only
-- _f 3"
7.6 cm)
48 In.2
A. Side view - closet or confined area
B. Recessed area
C. Closet door with vents
Recessed or closet installation - Stacked with stack kit
(Accessorial
±
12"
(30.5 cm}
m
m m
m m
_v
. .. DRYER
o
WASHER
--_-I'.,_- --_-I<- -='I I_'-
0" (0 cm) 0" (0 cm) 1" (2.5 cm)
A B
3" (7.6 cm)
J_
--i=_ I I<-
-- _ 3"
7.3 cm)
48In.=
24 In.2
C
A. Recessed area
B. Side view - closet or confined area
C. Closet door with vents
Mobile Home -Additional Location Requirements
This dryer issuitable for mobile home installations, The
installation must conform to the Manufactured Home
Construction and Safety Standard, Title 24 CFR, Part 3280
(formerly the Federal Standard for Mobile Home Construction
and Safety, "ntis245, HUD Part 280).
Mobile home installations require:
Metal exhaust system hardware which is available for
purchese from your dealer.
Special provialons must be made in mobile homes to
introduce outside air into the dryer. The opening (such as a
nearby window) should be at least twice as large as the dryer
exhaust opening.
Electrical Requirements
It isyour responsibility
Tocontacta qualifiedelectricalinstaller.
To be sure that the electrical connection is adequate and in
conformance with the National Electrical Code, ANSI/NFPA
70-latest edition and all local codes and ordinances.
The National Electric Code requires a 4-wire supply
connection for homes built after 1996, dryer circuits involved
in remodeling after 1996, and all mobile home installations,
A copy of the above code standards can be obtained from:
National Fire Proteotion Association, One Batterymarch Park,
Quincy, MA 02269.
To supply the required 3 or 4 wire, single phase, 120/240-volt,
60-Hz,, AC-only electrical supply (or 3 or 4 wire, 120/208-volt
electrical supply, if specified on the serial/rnting plate) on a
separate 30-amp circuit, fused on both sides of the line, A
time-delay fuse or circuit breaker is recommended, Connect
to an individual branch circuit, Do not have a fuse in the
neutral or grounding circuit,
Do not use an extension cord.
If codes permit and a separate ground wire is used, it is
recommended that a qualified electrician determine that the
ground path is adequate.
Electrical Connection
To properly install your dryer, you must determine the type of
electrical connection you will be using and follow the instructions
provided for it here,
This dryer is manufactured ready to install with a 3-wire
electrical supply connection, The green cabinst-grcunding
conductor ispermanently connected to the neutral conductor
(white wire) within the dryer, If the dryer is installed with a
4-wire electrical supply connection, the green cabinst-
grounding conductor must be removed from the external
ground conductor screw (green screw), and secured under
the neutral terminal (center or white wire) of the terminal
block, When the green cabinst-grounding conductor is
secured under the neutral terminal (center or white wire) of
the terminal block, the dryer cabinet is isolated from the
neutral conductor,
Use a 4-wire conductor cord when the dryer is installed in a
mobile home or an area where local codes do not permit
grounding through the neutral.