INSTAIJATIONINSTRUCTIONS
ToolsandParts
Tools needed
Gather the required tools and parts before starting installation.
Read and follow the safety instructions provided with any tools
listed here,
m Flat-blade screwdriver
= Level
= Adjustable wrench
m T2O Torx screwdriver
m Wire atripper (direct wire
installations)
= Wood block
m 7 mm nutdriver
m Caulking gun and
compound (for installing
new exhaust vent)
m Tin snips (new vent
installations)
m Vent clamps
= A grounded electrical outlet located within 2 ft (61 cm) of
either side of the dryer, See "Electrical Requirements,"
m A sturdy floor to support the dryer weight (dryer and load) of
115 Ibs (52 kg). The combined weight of a companion
appliance should also be considered.
= A level floor with a maximum slope of 1" (2.5 cm) under entire
dryer.
Do not operate your dryer at temperatures below 4,5°F (7°C). At
lower temperatures, the dryer might not shut off at the end of an
automatic cycle. Drying times can be extended.
The dryer must not be installed or stored in an area where it will
be exposed to water and/or weather.
Check code requirements. Some codes limit, or do not permit,
installation ofthe dryer in garages, closets, mobile homes, or
sleeping quarters. Contact your local building inspector.
Parts supplied
Remove parts package from the dryer drum, Check that all parts
listed are included,
Q
Coupling
Installation Clearances
The location must be large enough to allow the dryer door to
open fully.
Dryer Dimensions
Parts needed
Check local codes, existing electrical supply and venting, and
see "Venting Requirements" and "Electrical Requirements"
before purchasing parts.
Location Requirements
Explosion Hazard
Keep flammable materials and vapors, such as
gasoline, away from dryer,
Place dryer at least 18 Inches (46 cm) above the floor
for a garage Installation,
Fallura to do so can result In death, explosion, or flra,
You will need
a A location that allows for proper exhaust installation. See
"Venting Requirements."
a Aseparate3g-amp circuit.
*Most installations require a minimum 5½" (14.0 cm) clearance
behind the dryer for the exhaust vent with elbows. See "Venting
Requirements."
Minimum installation spacing for recessed area and closet
installation
The following dimensions shown are for the minimum spacing
allowed when the dryer is to be operated with, or without, the
Stack Kit. To purchase a Stack Kit, see "Assistance or Service."
m Additional spacing should be considered for ease of
installation end servicing.
m Additional clearances might be required for wall, door, end
floor moldings.
4