6.2.5 Set Line Crossing Detecon
It is used to detect objects crossing a pre-dened virtual line. If it occurs, the device can take
linkage acons.
Steps
1.
Go to Conguraon → Event → Smart Event → Line Crossing Detecon .
2.
Check Enable.
3.
Select one Line and set the size lter. For the size lter sengs, refer to Set Size Filter .
4.
Click Draw Area and a line with an arrow appears in the live video. Drag the line to the locaon
on the live video as desired.
5.
Set rules.
Direcon It stands for the direcon from which the object goes across the line.
A<->B: The object going across the line from both direcons can be detected and
alarms are triggered.
A->B: Only the object crossing the congured line from the A side to the B side
can be detected.
B->A: Only the object crossing the congured line from the B side to the A side
can be detected.
Sensivity It stands for the percentage of the body part of an acceptable target that goes
across the pre-dened line. Sensivity = 100 - S1/ST × 100. S1 stands for the
target body part that goes across the pre-dened line. ST stands for the complete
target body. The higher the value of sensivity is, the more easily the alarm can
be triggered.