Installation instructions
USING FLEXIBLE METAL DUCTS
If rigid all metal duct cammt be used, then flexible all metal
venting cart be used, but it will redtlce the maximum
recommended duct length. In special installations when it is
impossible to make connection with the above recomlnendations,
then UL listed clothes dryer transition duct may be used as
transition venting between the dryer and wall connection only. The
use of this ducting will aflect dry time.
If flexible transition duct is necessary, the fbllowing directions must
be followed.
Use the Shortest Length Possible.
Stretch the Duct to Its Maximmn Length.
Do Not Crush or Collapse.
Never Use _lYansition Duct Inside the Wall or
Inside the Dryer.
Avoid Resting the Duct on Sharp Objects.
Venting Must Conform to Local BuiMing Codes.
|
ELBOWHIGHLY
RECOMMENDED
ELBOWSHIGHLY
)(
DONOTUSE
EXCESSIVE
t
D0,0T\
_. CRUSH
FLEXIBLE
NEXHAUST
_ AGAINST
[] ALCOVE OR CLOSET INSTALLATION
o If yore' dryer is approved for installation in an alcove or
closet, it will be stated on a label on the dryer back.
o The dryer MUST be vented to the outdoors. See the
EXHAUST INFORMATION section.
o Mininmm clearance between dryer cabinet and adjacent
walls or other surfaces is:
0 in. either side
3 in. fl'ont and rear
o Minimum vertical space from floor to overhead cabinets,
ceiling, etc. is 52 in.
o Closet doors must be louvered or otherwise ventilated and
mtlst contain a minimum of 60 sq in. of open area equally
distribmed. If the closet contains both a washer and a
dryer, doors nmst contain a mininmm of 120 sq in. of open
area equally distributed
o The closet sbotfld be vented to the omdoors to prevent gas
pocketing in case of a gas leak in the supply line.
o No other tirol-burning appliance shall be installed in the
same closet with the dryer.
[] BATHROOM OR BEDROOM
INSTALLATION
6
o The dryer MUST be vented to the outdoors, See
EXHAUST INFORMATION section 6
o The installation nmst conform with local codes or, in the
absence of local codes, with the NATIONAL FUEL GAS
CODE, ANSI Z223
[] MOBILE OR MANUFACTURED
HOME INSTALLATION
oInstallation must conform to the MANUFACTURED
HOME CONSTRUCTION & SAFETY STANDARD,
TITLE 24, PART 32-80 or, when such standard is not
applicable, with AMERICAN NATIONAL STANDARD
FOR MOBILE HOME, NO. 501B,
oThe dryer MUST be vented to the outdoors with the
termination securely fastened to the mobile home
structure. (See EXHAUST INFORMATION section 6.)
oThe vent MUST NOT be terminated beneath a mobile or
manufactm'ed home.
oThe vent duct material MUST BE METAL.
*KIT 14-D346-33 MUST be used to attach the dryer
securely to the structure
oThe vent MUST NOT be connected to any other duct,
vent, or chimney.
oDo not use sheet metal screws or other refastening
devices which extend into the interior of the exhaust vent.
oProvide an opening with a free area of at least 25 sq, in.
for introduction of outside air into the dryer room.