Installation instructions
Minimum Clearance Other Than Alcove or Closet Installation
Minimum clearance to combustible surfaces and fox'air opening are: 0 in. clearance both skies and 1in. rear. Consideratkm
must be given to provkte adequate clearance for proper operation and service.
[] PREPARING FOR iNSTALLATiON
OF NEW DRYER
EXTERNAL
DUCT
OPENING
CSA(AGA)APPROVED
NEWFLEXIBLEGAS
LINECONNECTOR
GAS
INLET
PIPE
DUD]
TAPE
4"METALDUCT \
DUCT
TAPE
TIP: Install your dryer before installing your washer.
_[his will allow better access when installing dryer exhaust.
DiSCONNECTiNG GAS
TURNGAS . .__
SHUT-OFF
VALVETOTHE
OFFPOSITION.
DISCONNECTANDDISCARDOLD
FLEXIBLEGASCONNECTOR
ANDOLDDUCTINGMATERIAL.
Z_ WARNING - NEVERREUSE OLD
FLEXIBLE CONNECTORS.
The use of old flexible connectors can cause leaks and
personal injury. Always use new flexible connectors when
installing gas appliances.
REMOVING LiNT FROM WALL
EXHAUST OPENING
WALL
/
INTERNALDUCT CHECKTHATEXHAUST
OPENING OPENS
ANDCLOSESFREELY,
2
TILTTHEDRYERSIDEWAYS
ANDREMOVETHEFOAM
SHIPPINGPADSBY
PULLINGATTHESIDES
ANDBREAKINGTHEM
AWAYFROMTHEDRYER
LEGS,BESURETO
REMOVEALLOFTHE
FOAMPIECESAROUND
THELEGS.
[] GAS REQUIREMENTS
WARNING
. Installation must conform to local codes and ordinances,
or in their absence, the NATIONAL FUEL GAS CODE,
ANSI Z223.
. This gas dryer is equipped with a Valve & Burner Assem-
bly for use only with natural gas. Using conversion kit
WE25X0217, your local service organization can convert
this dryer fox'use with propane (LP) gas. ALL CONVER-
SIONS MUST BE MADE BY PROPERLY TRAINED
AND QUALIFIED PERSONNEL AND IN AC-
CORDANCE WITH LOCAL CODES AND ORDI-
NANCE REQUIREMENTS
. The dryer must be disconnected fl'om the gas supply
piping system during any pressure testing of that system
at a test pressure in excess of 05 PSI (3.4 KPa)
° The dryer must be isolated from the gas supply piping
system by closing the equipment shut-off valve during
any pressure testing of the gas supply piping of test
pressure equal to or less than 05 PSI (3.4KPa).
DRYER GAS SUPPLY CONNECTION
2"
I 24/8" 3/8"NPTMALETHREADGASSUPPLY
NOTE:Addtoverticaldimension
thedistancebetweencabinet
bottomtofloor.
GAS SUPPLY
A 1/8-in. National Pipe Taper thread plugged tapping, ac-
cessible for test gauge connection, must be installed imme-
diately upstream of the gas supply connection to the dryer.
Contact your local gas utility should you have questions on
the installation of the plugged tapping.
Supply line is to be 1/2-in. rigid pipe and equipped with an
accessible shut-offwithin 6 ft. of, and in the same room
with, the dryer.
Use pipe thread sealer compound or Teflon tape
appropriate for natural or LP gas.
You must use with this dwer a flexible metal connector listed
connector ANSI Z21.24 /CSA 6.10. The length of the
connect shall not exceed 3 ft.
Connect flexible metal connector to dryer and gas supply.
Open shut-offvalve_