Loading ...
Loading ...
Loading ...
Installation
[] ELECTRICAL CONNECTION
iNFORMATiON
WARNING- TO REDUCE THE RISK OF
FIRE, ELECTRICAL SHOCK, AND PERSONAL
INJURY:
DO NOT USE AN EXTENSION CORD OR AN
ADAPTER PLUG WITH THIS APPLIANCE.
Dryer must be electrically grounded in accordance with
local codes and ordinances, or in the absence of local
codes, in accordance with the NATIONAL ELECTRI-
CAL CODE, ANSI/NFPA NO. 70.
ELECTRICAL REQUIREMENTS
This appliance must be supplied with 120V, 60Hz, and connected
to a properly grounded branch circuit, protected by a 15- or 20-
amp circuit breaker or time-delay fuse. If electrical supply provid-
ed does not meet the above specifications, it is reconnnended that
a licensed electrician install an apt)roved outlet.
_WARNING - THIS DRYER IS EQUIPPED
A THREE-PRONG (GROUNDING) PLUG FOR
YOUR PROTECTION AGAINST SHOCK
HAZARD AND SHOULD BE PLUGGED
DIRECTLY INTO A PROPERLY GROUNDED
THREE-PRONG RECEPTACLE. DO NOT CUT
OR REMOVE THE GROUNDING PRONG
FROM THIS PLUG.
ENSURE PROPER GROUND EXISTS BEFORE USE.
(-
IFLOCALCODESPERMIT,
ANEXTERNALGROUNDWIRE
(NOTPROVIDED},WHICHMEETS
LOCALCODES,MAYBEADDED
BYATTACHINGTOTHEGREEN
GROUNDSCREWONTHEREAR
OFTHEDRYER,ANDTOA GROUNDED
METALCOLDWATERPIPEOROTHER
ESTABLISHEDGROUND.
instructions
[] EXHAUST iNFORMATiON
A
_WARNING - USE ONLY METAL 4-IN. DUCT.
DO NOT USE DUCT LONGER THAN SPECIFIED
IN THE EXHAUST LENGTH TABLE.
Exhaust longer than specified will:
Increase the drying times and the energy cost.
" Reduce the dryer life.
Accunmlate lint, creating a potential fire hazard.
The correct exhaust installation is your responsibility.
Problems due to incorrect installation a,,e not covered
by the warranty.
The MAXIMUM ALLOWABLE length of the exhaust system
depends upon the type of duct, number of turns, the type of
exhaust hood (wall cap), and all conditions noted below-. Both
rigid and flexible metal duct are shown in the table below:
No. of 90°
Elbows
0
1
2
3
4
5
EXHAUST LENGTH
RECOMMENDED MAXIMUM LENGTH
Exhaust HoodTypes
Recommended
Rigid Flexible
Metal Metal
150 Feet 55 Feet
135 Feet 52 Feet
125 Feet 49 Feet
115 Feet 48 Feet
105 Feet 43 Feet
95 Feet 40 Feet
Use onlyfor short
run installations
4" DIA.
[_2-1/2"
Rigid Flexible
Metal Metal
125 Feet 45 Feet
115 Feet 42 Feet
105 Feet 39 Feet
95 Feet 35 Feet
85 Feet 33 Feet
75 Feet 30 Feet
4
If using flexible metal duct, please refer to page 6.
EXHAUST SYSTEM CHECK LiST
HOOD OR WALL CAP
Terminate in amanner to prevent back drafts or entry of birds or
other wildlife.
Termination should present minimal resistance to the exhaust air flow
and should require little or no maintenance to prevent clogging.
Never install a screen in or over the exhaust duct.
Wall caps must be installed at least 12in. above ground level or any other
obstruction with the opening pointed down.
If roof vents or louvered plenmns are used, they must be equivalent to a
4-in. dampened wall cap in regard to resistance to air flow, prevention of
back drafts, and maintenance required to prevent clogging.
SEPARATION OF TURNS
Fox'best perfbrmance, separate all turns by at least 4 fL of straight duct,
including distance between last turn and dampened wall cap.
TURNS OTHER THAN 90°
One turn of45o or less may be ignored.
o
Two 45 turns should be treated as one 90oturn.
o o
Each turn over 45 should be treated as one 00 turn.
SEALING OF JOINTS
"All joints should be tight to avoid leaks. The male end of each section of
duct must point away fi'om the dryer.
*Do not assemble the ductwork with fasteners that extend into the duct.
They will serve as a collection point fbr lint.
"Duct joints should be made air-and moisture-tight by wrapping the
overlapped joints with duct tape.
"Horizontal runs should slope down towm'ds outdoors 1/2 inch pet"fbot.
INSULATION
Duct work that runs through an unheated area or is near air conditioning
should be insulated to reduce condensation and lint build up_
Loading ...
Loading ...
Loading ...