Stopping the alarm:
Short press on X key will stop the alarm from sounding and removes pop-up.
Setpoint temperature continues to blink while the temperature is still out of range. If the temperature
is within range and temperature alarm is active, the pop-up will be dismissed automatically.
Humidity
Humidity can be monitored or can be chosen not to in SETTINGS MENU. If it is set to 'OFF', then
humidity is no longer being monitored (not in the appliance and not in the mobile app). Display does
not show any humidity values.
Humidity alarm sounds when 7 days average value of compartment humidity falls below 40% or
rises above 80%, for 7 days constantly.
Hunidity value of compartment blinks, alarm pop-up is triggered.
INFORMATION!
Every time the appliance is switched on, it takes a while until the correct humidity is reached. For
this reason, the alarm is disabled for the first 24 hours after the appliance is switched on to prevent
the unnecessary activation of the alarm. Each time the door is closed, humidity alarm is blocked
for 6 hours.
If the difference between old setpoint and new setpoint is less than 5°C, it has no influence on
humidity alarm.
If setpoint temperature for any compartment is set above or equal to 16°C, humidity alarm is neglected.
Stopping the alarm:
Short press on X key will stop the alarm from sounding.
Humidity value continues to blink while the humidity is still out of range.
If humidity value reestablishes between 40% and 80% and humidity alarm is active , alarm pop-up
will be canceled automatically.
Open door alarm
Door alarm sounds and alarm pop-up is triggered when the door is open for more than 3 minutes
and there is no user interaction.
Short press on X key will stop alarm from sounding and alarm pop-up will be canceled. If you do
not close the door, the alarm will switch on again after 5 minutes.
Closing the door will stop the alarm.
Power outage high temperature alarm
If the electricity power in which the appliance is plugged in fails or outages then appliance stops
cooling and temperature inside the compartment can be affected.
The power failure alarm is designed to alert after power is restored and appliance turned on that the
temperature inside the compartment is out of range. If the temperature is not out of range, power
failure alarm will not be triggered. When the appliance is in a place not frequently visited or you are
away for a long time this alarm will help you be aware after restoring the appliance that the temperature
of the bottles might have changed.
Alarm sounds and Power failure occurred pop-up message is displayed.