RGBlink 981-1000-03-0 PTZ Camera Controller

User Manual - Page 11

For 981-1000-03-0.

PDF File Manual, 17 pages, Read Online | Download pdf file

981-1000-03-0 photo
Loading ...
Loading ...
Loading ...
© Xiamen RGBlink Science & Technology Co., Ltd.
Ph: +86 592 5771197 | support@rgblink.com | www.rgblink.com
10
(3) Language setting: Chinese and English
(4) Mode: VISCA, IP VISCA, ONVIF, PELCO
(5) Version information
(6) Restore factory settings
(7) Local IP
2.2.2 VISCA & IP VISCA Mode shared Setting
(1) F1: Custom function for F1 button (VISCA command)
(2) F2: Custom function for F2 button (VISCA command)
Input custom name
ENTER
Input VISCA command
For example: the command is 8101040702FF, then input 01040702 (0 cant be omitted)
2.2.3 IP VISCA Mode Setting
Delete the saved device:
Move the joystick up and down to view devices; Move the joystick rightward to view the device
s
port information; Move the joystick leftward to view the IP, CAM NUM information; ENTER to delete
the selected device.
2.2.4 VISCA Mode Setting
Control settings (set the baud rate for a certain address code):
Move the joystick up, down, left and right to switch addresses (1-7) ENTER Move the joystick left and
right to switch baud rate
ENTER
EX: Select the address: 1 ENTER Select the baud rate: 9600 ENTER
When the controller switch to address 1, the control baud rate is 9600
2.2.5 PELCO Mode Setting
Control settings (set the baud rate for a certain address code):
Move the joystick up, down, left and right to switch addresses (1-255)
ENTER
Move the joystick left and
right to choose protocols
ENTER
Move the joystick left and right to switch baud rate
ENTER
EX: Select the address: 1
ENTER
Select the protocol: PELCO-D
ENTER
Select the baud rate: 9600
ENTER
When the controller switch to address 1, the control baud rate is 9600, protocol is PELCO-D