Power Supply Cord,
Three=wire electrical connection:
A...................
Thisbladeconnectedto B
thisconductor. .........................................
EDC
A. Spade terminals with upturned ends
B. Ring terminals
C. Neutral (white or center)
D. 3/4" (1.9 cm) UL-listed strain relief
E. Neutral
Three-wire power supply cord must
have three, No.-10 copper wires and
match a three-wire receptacle of NEMA
Type 10-30R.
Use this method where local codes permit connecting
cabinet-ground conductor to neutral wire:
6. Loosen or remove the center terminal External
block screw, ground
7. Connect the neutral wire (white or center) screw
of the power supply cord under the
center, silver-colored terminal screw of Neutral
the terminal block. Tighten screw.
8. Connect the other wires to outer terminal
block screws. Tighten screws. Outer
9. Tighten strain relief screws, terminal
10. Insert tab of the terminal block cover into block
slot of the dryer rear panel. Secure cover screws /
with hold-down screw.
(green/yellow)
/
Strain Relief Screw
Center silver-colored
Neutral
wire
3/4" (1.9 cm)
U.L.-listed,
strain relief
Use this method where local codes do not permit
connecting neutral ground wire to neutral wire:
6. Remove the center terminal block screw.
7. Connect the neutral wire (white or center)
of the direct wire cable under the center
screw of the terminal block. Place the
hook-shaped end of the wire over the
terminal block screw. The open side of
the hook should face to the right.
Squeeze hook end of wire together to
form a loop.
8. Connect the other wires to outer terminal
block screws. Tighten screws.
9. Tighten strain relief screws.
10. Insert tab of the terminal block cover into
slot of the dryer rear panel. Secure cover
with hold-down screw.
11. After reattaching the terminal cover,
connect a separate copper ground wire
from the external ground conductor screw
to an adequate ground.
If codes permit and a separate ground wire is
used, it is recommended that a qualified
electrician determine that the ground path is
adequate.
External
ground
screw
Neutral
grounding wire
(green/yellow)
Outer
terminal
block
screws
/
/'
Strain Relief Screw
Center silver-colored
Neutral
wire
3/4" (1.9 cm)
U.L.-listed,
strain relief
12