4
- All Other Markets:
NOTE:
Measure burner operating pressure at manifold test point with two burners operating at 'High Flame'
setting.
NAT, LPG & Butane Only - Operating pressure is ex-factory set and is not to be adjusted, apart from
when converting between gasses, if required.
TOWN GAS Only - Burner operating pressure is to be adjusted using the adjustable gas regulator
supplied.
Refer to ‘Gas Conversion and Specifications’ section in this manual for further details.
Input Rate (N.H.G.C.)
- each Open Burner
22 MJ/hr 22 MJ/hr 22 MJ/hr 22 MJ/hr
- each 300mm Griddle Section
20 MJ/hr 20 MJ/hr 20 MJ/hr 20 MJ/hr
- Static Ovens
CR6
24 MJ/hr 24 MJ/hr 24 MJ/hr 24 MJ/hr
CR9
28 MJ/hr 28 MJ/hr 28 MJ/hr 28 MJ/hr
Supply Pressure 1.13 - 3.40 kPa 0.75 - 1.50 kPa 2.75 - 4.50 kPa 2.75 - 4.50 kPa
Burner Operating Pressure (*) 1.0 kPa 0.63 kPa 2.6 kPa 2.6 kPa
Gas Connection ¾” BSP Male