23
- NAT Gas / LPG / Butane Only.
NOTE:
The regulator supplied is convertible between
Natural Gas and LP Gas, but it’s outlet pressure is
fixed ex-factory and is NOT to be adjusted.
1. Ensure that the gas supply is turned 'Off' at the
mains.
2. Unscrew the hexagonal cap (23mm A/F) from
the regulator.
3. Un-clip the plastic pin from the cap, reverse the
pin and re-fit it back to the cap the correct way
for the gas type to be used. (Either ‘LP’ or ‘NAT’
should be visible on the flank of the pin once
re-fitted to the cap).
4. Screw the cap back into the regulator hand
tight only.
- Town Gas Only.
1. Unscrew and remove slotted cap from regulator.
2. Turn ‘On’ gas supply and appliance.
3. Adjust pressure adjusting nut to achieve correct
burner operating pressure.
NOTE:
Operating pressure is to be measured at the
manifold test point and with 2 burners operating at
the ‘High Flame’ setting.
4. Verify operating pressure remains correct
(Re-adjust the regulator if required).
5. Screw cap nut back onto regulator.
Pressure Adjusting
Screw
Cap Nut
On completion of gas conversion, replace gas type
identification label located at:-
- Rear of appliance, above gas connection.
- Beside the rating plate.
Before leaving the converted installation;
1. Check all gas connections for leakages using
soapy water or other gas detecting equipment.
2. Check the following functions in accordance
with operating instructions specified in the
'Operation' section of this manual.
Lighting the Open Burners.
(Standard / Flame Failure Option).
Lighting the Open Burners.
(Pilot / Pilot with Flame Failure Option).
Check Low Fire burner operation.
Check High Fire burner operation.
Lighting the Griddle (If fitted).
Check Griddle Burner operation (If fitted).
Ensure that all controls operate correctly.
Ensure that operating pressure remains
correct.
3. Ensure any adjustments done to components
that have adjustments / settings sealed
(e.g. paint sealed), these are re-sealed.
NOTE:
If it is not possible to get the appliance to operate
correctly, shut ‘Off’ the gas supply and contact the
supplier of this appliance.
DO NOT USE A NAKED FLAME TO CHECK FOR GAS LEAKAGES.