About the water softener system.
Feature/Service: Automatic Electronic Diagnostics
The timer computer has a self-diagnostic function for the electrical sgstem (except input power and
water meter). The computer monitors the electronic components and circuits for correct operation.
Ifa malfunction occurs, an error code appears in the timer displag.
The chart on Error Codes shows the error codes that could appear and possible defects for each code.
While an error code is displaged, the TOUCH or HOLD and DATA buttons remain operable so gou can
perform the Manually Initiated Electronic Diagnostics.
ERROR CODE DISPLAYED ERR01 ERR02 ERR03 ERR04 ERR 05
POSSIBLE DEFECT _ motor inoperative _ wiring harness, or connection to switch _ timer (PWA)
position switch _ valve defect causing high torque
To remove an error code: (1)Unplug transformer
(2)Correct defect.
(3)Plug transformer in.
{4)Wait for at least 6 minutes. Theerror codewill return if the reason
for the error codewas not corrected.
REMAININGCAPACITY
FLOWRATEGPM
GALLONSTODAY
AVG.DAILY GALLONS
Feature: Other Data Displays
Ogcontinuing to press the DATA button, gou can scan through four displags of operational
information. This data appears in the bottom portion of the displag area.
REPIAINING CAPACITY -- _ This is the percentage of water softening capacitg remaining.
Immediatelg after a regeneration, 100% shows. As water is used, the percentage decreases until the
next regeneration. During regenerations, the percentage increases.
NOTE: Zero (%)shows until after the first regeneration begins, offer connecting to
electrical power
FLOW RATE,GPPI-- _ When using soft water, this displag shows the flow rate passing through
the softener (in gallons per minute). Zero shows if water is not passing through the softenen
GALLONS TODAY-- _ Each dag, beginning at midnight, the timer keeps a running count of the
total gallons of water that have passed through the softene,
AVG. DAILY GALLONS- _ The figure displaged is the average gallons of water used bg the
household each dag over the past seven dag period.
NOTE: If preferred, gou can set the timer to show the reading in liters instead of gallons. If GALLONS
TODAY or AVG. DAILY GALLONS exceeds 1999, a (xlO) indicator appears; this means gou must
multiplg the number shown bg ten.