33
120min 120min 120min
0~120
min
Boost
Duration
--- ---
28
days
0-30
days
Equalization
Interval
--- --- 120min
0~120
min
Over-
voltage
Recover
Variable
until Full
---
---
120min
28
days
0-120
min
14.6V 14.2V 14.6V
13.2V-
15.5V
Boost
Charge
Voltage
13.8V 13.8V 13.8V
13.2V-
15.5V
Float
Charge
Voltage
--- --- 14.8V
13.2V-
15.5V
Equalization
Voltage
13.2V 13.2V 13.2V N/A
Boost
Return
Voltage
12V 12V 12V N/A
Under
Voltage
Warning
12.2V 12.2V 12.2V N/A
Under
Voltage
Recover
11.1V 11.1V 11.1V N/A
Over-
discharge
Warning
12.6V 12.6V 12.6V
14.4V
(adjustable)
---
---
13.2V
12.1V
12.2V
11.1V
12.6V
Battery Charging Chart
Battery
Type
Parameters
SLD/
AGM
16V 16V 16V
N/A
GEL
FLD
Custom
Range
(USER/LI)
Over-
voltage
Warning
15.5V 15.5V 15.5V N/A
Charging
Limit
Voltage
16V
LI
(LFP)
15.5V
16V
USER
(Default)
15.5V
15V 15V 15V N/A
Over-
voltage
Recover
15V 15V
14.6V
(adjustable)
13.8V
(adjustable)
14.6V
(adjustable)
13.2V
12V
12.2V
11.1V
12.6V N/A
Over-
discharge
Recover
Loading ...
Loading ...