7. Usingguidescrewtolocateholein rearofblower
housingpositiontransitioninsideblowerhousing.
Rotatetransitionuntilholeinfrontofblowerhousing
isaligned.Securetransitionwithscrewprovided.
8. Sealallductjointswithducttape.
9. Checkunderrangetobesurelevelinglegisfully
engaged in the anti-tip bracket.
10. Instafl storage drawer.
Gas Connection Requirements
Before connecting this appliance to the gas supply piping
system, confirm installationmeets the requirements of local
codes, or in the absence of local codes, with the National
Fuel Gas Code, ANSi Z223.1 -Latest Edition.
When installed in mobile housing, installation is to be in
accordance with CSA standard Z241.1 gas equipped
mobile housing.
The installation of appliances designed for manufactured
(mobile) home installation must conform with
Manufactured Home Construction and Safety Standard,
Title 24 CFR, Part 3280, or when such standard is not
applicable, the Standard for Manufactured Home
Instaflation, ANSI225.1/NFPA 501 A-Latest Edition, or with
local codes or the standard CAN/CSA-z240MH, "Mobile
Homes", and with local codes where applicable.
The instNlation of appliances is to be in accordance with
CAN1 =B149.1 or B149.2 installation code for gas burning
appliances and equipment and/or local codes. Part 1 and/
or local codes.
Pressure Regulator Location
Remove the storage drawer and locate regulator under
oven cavit'r inrear.
,/
1
Gas Connection (Natural Gas Only)
Connect gas supply to regulator using hard pipe or flexible
connector (Check local codes). Pressure regulator
supplied with this appliance has al/2 inch NPT female
connection. If gas union is used, remove storage drawer,
slide range into place, and connect union.
® A manuN shutoff, not supplied with range, must be
installed in an accessible location outside of range.
® Use joint compound on all male pipe threads.
® Use supplied pressure regulator only.
® Do not overtighten gas fitting when attaching to
pressure regulator. Overtightening may crack regulator.
® Support pressure regulator with wrench when instNling
gas fitting.
WARNING !
To avoid property damage or personal injury, only use
a new flexible connector that is AGA/CGA design
certified.
Do not use an old connector.
Do not reuse a connector after moving appliance.
A B
A Regulator
B_Flexibte Connector
C_Manual Shut Off Valve
D_Adaptor
Flexible Connection
insure red tab
REMAINS in the
OPEN or On
position during
installation.
Pressure Regulator Location