To remove and attach the BioClip plug on
cutting deck Combi 103 and 112
1. Put the cutting deck in servicing position.
2. Remove the 3 screws that hold the BioClip plug and
remove the plug.
3. Attach 3 M8x15 mm screws in the screw holes for
the BioClip plug to prevent damage to the threads.
4. Put the cutting deck back in mow position.
5. Attach the BioClip plug in the opposite sequence.
To remove and attach the BioClip plug on
cutting deck Combi 94
1. Put the cutting deck in servicing position.
2. Remove the 3 screws that hold the BioClip plug and
remove the plug.
3. Put the cutting deck back in mow position.
4. Attach the BioClip plug in the opposite sequence.
To examine the blades
CAUTION:
Damaged or incorrectly
balanced blades can cause damage to the
product. Replace damaged blades. Let an
approved service agent help you sharpen
and balance blunt blades.
1. Put the cutting deck in servicing position.
2. Look at the blades to see if they are damaged and if
it is necessary to sharpen them.
3. Tighten the blade bolts with tightening torque 45–50
Nm.
To replace the blades
1. Put the cutting deck in servicing position.
2. Lock the blade with a wooden block (A).
A
C
D
B
3. Loosen and remove the blade bolt (B), the washers
(C) and the blade (D).
4. Assemble the new blade with the ends that have an
angle in the direction of the cutting deck.
WARNING:
Incorrect blade type
can cause objects to eject from the
cutting deck and cause serious injury.
Use only the blades given in
Technical
data on page 115
.
5. Attach the blade, the washer and the bolt. Tighten
the bolt with a torque of 45–50 Nm.
To do a check of the engine oil level
1. Park the product on level ground and stop the
engine.
2. Open the engine cover.
3. Loosen the dipstick and pull it out.
838 - 010 - 15.03.2022