41
3. Set Sensitivity. The higher the value is, the more easily the defocus image can trigger the alarm.
You can adjust the value according to the actual environment.
4. For the linkage method settings, refer to Linkage Method Settings.
5. Click Save.
Note
The function is only supported by certain models. The actual display varies with models.
6.2.3 Detect Scene Change
Scene change detection function detects the change of video security scene. Some certain actions
can be taken when the alarm is triggered.
Steps
1. Go to Configuration → Event → Smart Event → Scene Change Detection.
2. Click Enable.
3. Set the Sensitivity. The higher the value is, the more easily the change of scene can be detected.
But the detection accuracy is reduced.
4. Refer to Set Arming Schedule for setting scheduled time. Refer to Linkage Method Settings for
setting linkage method.
5. Click Save.
Note
The function varies according to different models.
6.2.4 Set Face Detection
It helps to detect the face in the detection region. If a face is detected, the device triggers the
linkage actions.
Steps
1. Go to Configuration → Event → Smart Event → Face Detection.
2. Check Enable Face Detection.
3. Optional: Highlight to display the face in the image.
1) Check Enable Dynamic Analysis For Face Detection.
2) Go to Configuration → Local, set Rules to Enable.
4. Set Sensitivity. The lower the sensitivity is, the profile of the face or unclear face is more
difficult to detect.
5. Set the arming schedule and linkage methods. For the information about arming schedule
settings, see Set Arming Schedule. For the information about linkage methods, see Linkage
Method Settings.
6. Click Save.