Network Camera User Manual
98
10.5 Queue Management
It is used to count queuing-up people number and waiting time of each person.
Note
Queue management is only supported by certain models.
10.5.1 Set Regional People Queuing-Up
It is used to count queuing-up persons in defined regions. Alarms are triggered when the alarm
threshold condition and the alarm trigger are both met.
Before You Start
To enable the function, go to VCA Resource, and select Queue Management.
Steps
1. Go to Configuration → Queue Management.
2. Select Regional People Queuing-Up.
3. Click Add Region to draw the detection area and set Region Name and Alarm Interval. Repeat
this step above to set more areas.
Alarm Interval
During the set alarm interval, alarms of the same type only trigger one notification.
Figure 10-2 Set Regional People Queuing-Up
4. Optional: Check OSD to display the region name and its real-time queuing-up people number.
5. Set Alarm threshold. An alarm is triggered when the alarm threshold condition is met.
6. For the arming schedule settings, refer to Set Arming Schedule. For the linkage method settings,
refer to Linkage Method Settings.
7. Click Save.