4
12. Switch key for the second function (2nd): Enables the second function of other
keys.
13. Store key for the second function (Save): Stores the present operating states in
location “0”, “1”, … “9”.
14. Recall key for the second function (Recall): Recalls a previously stored operating
state from location “0”, “1”,…“9”.
15. Error key for the second function (Error): Checks or reads the error codes.
16. Local key for the second function (Local): Returns the power supply to local
mode from remote control mode.
17. Secure key for the second function (I/O config): Secures and unsecures the power
supply for calibration.
18. Number key (0-9 and.): Sets values.
19. Clear key for the second function (Clear): Clears present input value or exits
current operation.
20. Enter key (Enter): Confirms present setting values or option.
21. Display screen: Shows parameters and status of power supply.
22. ERR annunciator: When some error is detected, ERR annunciator is on.
23. REM annunciator: When the power supply is in remote control mode, REM
annunciator is on.
Front-Panel Display Messages
0.000V Display present voltage value.
0.000A Display present current value.
0.000W Display present power value.
OT The power supply is in over-temperature state.
OV The power supply is in over-voltage state and the supply output is
disabled.
OFF The output of power supply is off.
ERROR Hardware or remote interface control commands errors are detected and
the error bits have not been cleared or read.
Unreg The present output of the power supply is unregulated. (The output is
neither CV nor CC.)
CV The output of power supply is in CV mode.