6
NOTE: ALL ELECTRICAL CONNECTIONS MUST ONLY BE CARRIED OUT BY AN AUTHORISED
PERSON.
Each appliance should be connected to an adequately protected power supply and isolation switch mounted
adjacent to, but not behind appliance. This switch must be clearly marked and readily accessible in case of
fire.
1. Check that electricity supply is correct as shown on Rating Plate
attached to lower front R/H side of front sill panel.
2. Supply terminal connections are located at rear of appliance.
Refer to Electrical Connectionsin Specificationssection of
manual.
3. Open door and remove control panel to allow connection access
for electrical supply.
4. Bring supply cable up through compression type gland provided
on rear of main electrical switchgear panel.
5. Connect mains supply to L1, L2 and L3 connections for 3 phases.
Refer to 'Electrical Supply Requirements' section for connection
details.
6. Connect neutral and earth conductors to neutral stud and earth
stud respectively.
7. For all connections ensure that conductors are secure and
appropriately terminated.
8. Tighten cable gland to secure against tension on cable.
NOTE:
This appliance must be earthed.
Fixed wiring installations must incorporate an all-pole disconnection switch.
9. Correctly locate appliance into its final operating position and using a spirit level, adjust legs so that
appliance is level and at correct height.
10. Connect power supply to appliance.
11. Check electrical supply is as shown in Specificationssection.
Fig 1
Rating Plate
Location
THIS APPLIANCE MUST BE EARTHED. IF SUPPLY CORD IS DAMAGED, IT MUST BE REPLACED BY A SUITABLY
QUALIFIED PERSON IN ORDER TO AVOID A HAZARD.