SIGLENT
196 SDS2000X User Manual
12. Press the Apply softkey to perform the efficiency analysis. When the analysis has
completed, the results are displayed as shown below.
Figure 134: Perform Efficiency Analysis
The input voltage, input current waveforms, output voltage and output current waveforms
are displayed, as well as the calculated input power, output power and efficiency:
Input Power = Input V * Input I
Output Power = Output V * Output I
Efficiency = Input Power/ Output Power