GE - General Electric AZ58H15DACM1 GE zoneline air conditioner

User Manual - Page 9

For AZ58H15DACM1.

PDF File Manual, 24 pages, Download pdf file

Loading ...
Loading ...
Loading ...
ge.com
Door Sensor (Obtained locally)
_]/en connected, tile door sensor will detect
when tile door in tile i'OOill w;is opened or
closed. This teatm'e must be used in coI_junction
with tile motion sensor:
Tile door and i/lotion sensoi3 work together
to autonmticallx tm'n tile refit ON or OFE
_ leo IS _l o_ I _ _ _ ° _ _ °
g g
_DoorSensor
External Fan(Obtainedlocally)
X4]/en connected, an auxiliary or external tim
can be controlled with tile indoor tim motor
on the Zoneline, Com_ections provide 94 V AC
to energize a remote relay, turning on the
external tim.
_ ExternalFan
Central Desk Control
X_]/en com_ected, tile refit can be turned ON
or OFF with a switch located at tile Central
Control Panel. A separate wire pair inust be
run fi'om each separate controlling switch to
each individual Zoneline.
hi®®®®®®®l®l®l®l®J;;l®
g
_CentraIDeskControi
Remote Thermostat
X_q/en connected, tile refit _fill be controlled
bv a i'elllote thermostat.
NOTE'The number 4 dip switch must be in tile
enabled (UP)position to activate tile remote
them_ostat, (See the installation instructions
supplied with tile remote them_ostat).
IMPORTAN7?
Tile Zoneline them_ostat connections
provide 24 V AC only
If using a digital/electronic wall them_ostat,
you must set it to tile 24 V AC setting.
See tile Installation Instructions for tile
wall them_ostat.
**q;H;l*lq;I.Iq.lq
zm
oRed 24VAConly
Green-LowSpeedFan
Green HighSpeedFan
Black-Solenoid
Yellow Compressor
White- Heater
CommonGround
CAUTION:
Damage to a wall them/ostat or to tile
Zoneline electronics can result fi'om improper
connections. Special care must be used in
cmmecting blue and black wires. No line w)ltage
connections should be made t() any circuit.
Isolate all wires in building fl'om line w)ltage.