Temperature Limiting
Temperature limiting can reduce energy' costs
by limiting the lowest temperature that can be
set fl)r cooling and the highest temI)erature that
can be set fin" heating. Temperature limiting is
controlled by switches 1-6 on the second block
of au_lia_ ycontrols. Tile fit_t three switches are
used to select the cooling limits, The next three
switches are used to control tile heating limits,
This teature is not available with tile Remote
Them_ostat-Class 2.
TL1(C)(Temp.Limit1-Cool)___.1"
TL2(C)(Temp.Limit2-Cool)
TL3(C)(Temp.Limit3-Cool)
0oqaelelee e ele j! mW alo ,
TL1(H)(Temp.Limit1-Heat)_
TL2(H)(Temp.Limit2-Heat)
TL3(H)(Temp.Limit3-Heat)
Temperaturelimiting during COOLmode
(all temperatures shown in °F)
UP DOWN Minimum Maximum
NONE 1,2,3 60° 85°
1 2,3 64° 85°
1,2 3 66° 85°
2 1,3 68° 85°
2,3 1 70° 85°
1,2,3 NONE 72° 85°
1,3 2 74° 85°
3 1,2 76° 85°
Temperature limiting during HEATmode
(all temperatures shown in °F)
UP DOWN Minimum Maximum
NONE 4,5,6 60° 85°
4 5,6 60° 80°
4, 5 6 60° 78°
5 4,6 60° 76°
5,6 4 60° 74°
4,5,6 NONE 60° 72°
4, 6 5 60° 70°
6 4, 5 60° 65°
Heat Sentinel
_,_]/eil this switch is enabled (UP), it turns ON
tile heat sentinel protection feature. _,_]tl/tile
switch disabled (DOWN), tile heat sentinel is
de-actiwated. This teature automatically provides
cooling without user interlhce. This helps to
prevent an excessively hot room by turning tile
air conditioner ON at 85°F and OFF at 80°E
oqaaaaaaaaliaaaaaa @l ,
HeatSentinelJ
Heat Boost
_,_q/en this switch is enabled (UP) and outdoor
temperatures are between 20 ° F and 46 ° F, heat
pump only operation is locked out. This setting is
used to provide SUl)l)lementm T heat to tile heat
pump operation in conditions where tile heat
pump only operation is not sufficient to maintain
a consistent, coi/ltOrtable i'ooi/l telill)ei'attli'e to
tile ('onstllllei;
.....o.[aaaaaaaallaaaaaaa al
BOOST(HeatBoostOperation)-]
DiagnosticsCheck-For Technician'sUseOnly
_,_q/en this switch is enabled (UP), tile refit will go
through an operations check of all components,
which takes about 3 I//intltes (176 seconds).
This diagnostic tool is intended fin" rise bv
a qualified technician.
DIAGNOS(DiagnosticCheck)J