Installation Instructions
REPLACING AN EXISTING UNIT?
Use the correct wall case
Checkthe "Essential
Elements"labelfor
importantinformation.
This unit is designed to be installed in a GE plastic or
insulated metal wall case. This minimizes condensation
from fimning on the room side of the case.
If the current wall case is not insulated, you can reduce
the possibili b' of condensation fimning 1)yinst;flling
insulation kit ILM(901 I,, a\:filable where you purchased
the unit.
Use the correct outdoor grille
You should use the outdoor grilles shown on the
"Essential Elements" label on the top of the unit.
If an existing grille is not replaced, capaci_' and
efficiency will be reduced and the unit may tail to
operam propedy or fifil prematurely: A deflector kit,
I_K40, may be used with grilles that were not designed
fin" w>ur new GE Zonelines. The ]_M(40 contains air
cleflectots and gaskets that mount to the trait m direct
the hot exhaust air away fl'om the air intake to allow
the unit to flmction properl> The grille inust have
a 65% minimum fl'ee area.
Any vertical deflectors in the existing rear grille should
be reilloved to decrease condenser air recirctllation
which can cause the trait to "short-cycle" and lead
to pi'ei/latui'e COll/ponent Jilihlre.