Before YouCall ForService...
Troubleshooting -tips
Problem Possible Causes What To Do
The air does not feel The heat pump alone *Use tile Electric Heat Option. This turns off tile
warm enough during produces air that feels heat l)mnl _ and warms with electric heat only.
heating operation cooler thm_ desired. NOTE: Use of this option Wl//result In increased energy
consumption.
Temperaturedisplay The compressor may
flashes have failed. Set tile mode control to STOP and then restart tile
unit. If tile flashing light reappears within 30 minutes,
call fin" service.
Thingsthatare normal
Normal Operating Sounds
PING! POP! You may hear a pinging noise caused by water being
picked up and thrown against the condenser on
rainy da):s or when the humidi U is high. This design
teatm'e helps remove moisture and improve
efficiency.
"CLICK" Ybu max hear relax_ click when tile controls cxcle
on and off or are a(!iusted to change the room
temperature.
DRIP
6X&_aterwill collect in tile base pan dtwing high
humidit_ or on raim days. Tile water may oxertlow
and drip fl'om tile outdo(>r side of tile refit.
WHIR./ Tile indoor tim runs continuously when tile refit is
operating in tile cooling mode, unless tile lira switch
behind tile room cabinet is set at tim cycle (up).
This will cause tile tim to cycle on and off with tile
compress(n: You may also hear a t_lll noise stop
and stm*.
_m may notice a few minutes delay in starting if you
try to restmX the Zoneline too soon after turning it
off or if you a(!iust the themaostat right atter the
compressor has shut off. This is due to a built-in
restart protector fl)r tile compressor that causes
a S-minute delay:
Dm'ing tile deti'ost cycle, both indoor and outdoor
rims stop and tile compressor will operate in tile
cooling illode to i'eil/ove ti'ost J[i'Oiil tile O/lt(looI" coil.
_Mter defi'ost, tile trait will restart in electric heat to
quickly warm tile room to tile desired comfort level.
2O
COMPRESSOR
PROTECTION
To protect tile compressor and prevent short
cycling, tile refit is designed to rtm fi)r a minimum
of 3 n/inutes, alter tile compressor starts at am'
themaostat setting.