V-Tac SUN-8K-SG01LP1-EU 8kW On/Off Grid Hybrid Solar Inverter

INSTRUCTION MANUAL - Page 37

For SUN-8K-SG01LP1-EU.

PDF File Manual, 50 pages, Read Online | Download pdf file

SUN-8K-SG01LP1-EU photo
Loading ...
Loading ...
Loading ...
Grid Setting/V(W) V(Q)
V(W) V(Q)
V1
109.0%
P2
V2
110.0%
P3
P4
V3
111.0%
V4
111.0%
P1
100%
20%
20%
20%
Lock-in/Pn Lock-out/Pn
V1
90.0%
Q2
V2
95.7%
Q3
Q4
V3
104.3%
V4
112.2%
Q1
44%
0%
0%
-60%
Grid
Set5
V(W): It is used to adjust the inverter active power
according to the set grid voltage.
V(Q): It is used to adjust the inverter reactive power
according to the set grid voltage.
This function is used to adjust inverter output power
(active power and reactive power) when grid voltage
changes.
For example: V2=110%, P2=20%. When the grid voltage reaches the 110% times of rated grid voltage,
inverter output power will reduce its active output power to 20% rated power.
For example: V1=90%, Q1=44%. When the grid voltage reaches the 90% times of rated grid voltage,
inverter output power will output 44% reactive output power.
For the detailed setup values, please follow the local grid code.
Grid Setting/P(Q) P(F)
P(Q) P(PF)
P1
0%
Q2
P2
0%
Q3
Q4
P3
0%
P4
0%
Q1
0%
0%
0%
0%
P1
0%
PF2P2
0%
PF3
PF4
P3
0%
P4
0%
PF1
-2.400
0.000
0.000
6.000
Grid
Set6
P(Q): It is used to adjust the inverter reactive power
according to the set active power.
P(PF): It is used to adjust the inverter PF according
to the set active power.
For the detailed setup values, please follow the local
grid code.
Lock-in/Pn Lock-out/Pn
Grid Setting/LVRT
L/HVR
HV1
115%
LV1
50%
Grid
Set7
Reserved: This function is reserved.It is not
recommended.
5%
20%
50%
50%
Lock-in/Pn 5%: When the inverter active power is less
than 5% rated power, the VQ mode will not take eect.
Lock-out/Pn 20%: If the inverter active power is
increasing from 5% to 20% rated power, the VQ mode
will take eect again.
Lock-in/Pn 50%: When the inverter output active power
is less then 50% rated power, it won't enter the P(PF)
mode.
Lock-out/Pn 50%: Lock-out/Pn 50%: When the inverter
output active power is higher then 50% rated power, it
will enter the P(PF) mode.
Note : only when the grid voltage is equal to or higher
than 1.05times of rated grid voltage, then the P(PF)
mode will take eect.