3 Installation (cont'd)
3.5 Connecting the Controls (energized by unit, low voltage)
Controls are not included with this unit.
Unit may be connected to a dry contact Standby switch if desired. In such case, unit remains powered on, but is put in
Standby mode when the switch is turned on.
This ERV can replace up to 2 bath fans. Where this is the case, unit should be connected to a 20-minute override control in
each bathroom.
3.5.1 Connecting unit to a Standby switch
Install the dry contact Standby switch in a convenient place and connect it to unit as follows.
3.5.2 Connecting unit to 1 or 2 Broan VB20W 20-minute push-button control(s)
1. Install the 20-minute push-button control in the bathroom(s) following instructions included with the control.
2. Connect it to unit as follows.
R RED
Y YELLOW
B BLACK
G GREEN
R RED
Y YELLOW
B BLACK
G GREEN
G
R
B
Y
VE0357A
G
R
B
Y
OL
OC
I
VE0358A
OL
OC
I
ON ON
CAUTION
Ensure all unused wires are capped off.
Switch position Unit mode
Dry contact ope-
ned
Unit will run in the
selected mode
Refer to 4.1
Dry contact closed
Unit is kept in
Standby mode
3.5.3 Connecting unit to a Standby switch AND 1 or 2 Broan VB20W 20-minute push-button control(s)
1. Install the 20-minute push-button control in the bathroom(s) following instructions included with the control.
2. Install the Standby switch in a convenient place.
3. Connect both with the unit as follows.
R RED
Y YELLOW
B BLACK
G GREEN
G
R
B
Y
OL
OC
I
BROAN VB20W
20-MIN.
PUSH-BUTTON CONTROL
DRY CONTACT
STANDBY SWITCH
VE0359A
ON
ON
I
OC
OL
This connection allows the operation of VB20W push-button controls even if the dry contact standby switch is turned off.
Switch position Unit mode
Dry contact ope-
ned
Unit will run in the
selected mode
Refer to 4.1
Dry contact closed
Unit is kept in
Standby mode