Thermocouple Probe : -40˚C to 230˚C (-40˚F to 450˚F)
Accuracy : Below –18˚C (0˚F) :+/-4F
From –18˚C –100˚C (0˚F to 212˚F) :+/- 2˚F
Above 100˚C (212˚F) :+/-4˚F
Ambient Operating Range : 32˚F to 122˚F (0˚C to 50˚C)
Elevated Operating Range : 1 Minute @ 160F (71C) ambient air
Thermocouple Sensor : Type K Chromel Alumel, ungrounded
Thermal Time Constant : (TTC=63.2%) in liquid : 1 second
Response Time : (90%=TTC*2.3 in liquid 2.3 seconds
LCD Display Size : Visable Area: 1 3.8” x 7/8”
Probe Dimensions Length : 110 mm
Dia : 3.5mm
OPERATIONAL
Repeatability : Below -18˚C (0˚F) ±4˚F
From -18˚C to 100˚C (0˚F to 212˚F) ±2˚F
above 100˚C (212˚F) ±4˚F
Ambient Operating Range : 0˚C to 50˚C (32˚F to 122˚F),
1 min @71˚C (160˚F)
Relative Humidity : 90% (=/5%) RH non-condensing @ 30˚C (86˚F)
Storage Temperature : - 20˚C to 60˚C (-4˚F to 140˚F)
Weight : 4.3 ozs
Power : Three AAA Batteries
Max Dimensions : Ht : 7.5 inches (190mm)
Width : 2.1 inches (52mm)
Thickness : 10.77 inches (19.5mm)
Battery Life : approx 10hrs continous usage
Blacklight LED : white
LCD type : Reverse LCD
Standards and Certifications : IP44 Sealing , hand washable, splash proof,
non-submersible. All other certifications to
be added. NSF Listed with logo
OPERATIONAL
POWER: To turn unit on simply open the probe to the extended position
and the LCD will illuminate.
SHUT OFF: The unit will shut off when the probe is returned to the closed
position.
AUTO SHUT OFF: To save battery life the unit will automatically shut off
after three minutes if there is no change in temperature. In order to reset
the unit simply close and reopen the probe.
FARENHEIT AND CELCIUS SCALES
On the back of the unit there is a opening below the icon ˚F/˚C. Using a
pen tip or smaller probe press once and the unit will switch from ˚F to ˚C.
The unit will remain in the ˚F or ˚C mode until switched back. When
batteries are replaced it will return to the default mode of F.
NORMAL TEMPERATURE MODE:
When the unit probe is extended it will show the Normal temperature in
the room. The thermometer is constantly reading and updating the
temperature in real time. Current temperature will be displayed on the LCD.
To destroy harmful bacteria like Salmonella and E Coli the USDA
recommends the following minimum internal temperatures:
(Beef, Veal, Lamb Steaks & Roasts and Fish) to be 145 °F
(Egg Dishes, Pork and Ground Beef, Veal & Lamb) to be 160 °F
(Turkey, Chicken & Duck Whole, Pieces & Ground) to be 165 °F
CLEANING AND CARE INSTRUCTIONS:
CLEANING:
The PT-100 ProTemp thermometer is dust proof and splash proof to IP44
standards as stated in the specification. Use a damp sponge or cloth to
clean the unit and probe. You may also dip the cloth or sponge in warm
soapy water to help remove surface deposits and prevent them from
becoming hard or sticky on the unit.
Cautions:
Do not use solvent based cleaners or methylated spirits.
Do not submerse the thermometer in liquid.
Do not place in a dishwasher.
Not Intended for Use by Persons ages 12 and Under
Warning:
Thoroughly clean thermometer after each use to avoid cross contamination.
When measuring high temperature items personal protection such as
gloves should be used.
DO NOT ATTEMPT TO RECALIBRATE THE UNIT.
CHANGING THE BATTERIES
On the back of the unit is a slide lock that opens the battery compartment.
The unit uses 3AAA batteries. Do not mix old and new batteries.
MAVERICK
Pro Temp
Professional
Thermometer
MODEL # PT-100
MAVERICK
Pro Temp
Professional
Thermometer
MODEL # PT-100
MAVERICK LIMITED 1 YEAR WARRANTY
Maverick Industries Inc. warrants this product to be free of defects in
parts, materials and workmanship for a period of 1 year, from date of
purchase. Should any repairs or servicing under this warranty be required,
contact Maverick Customer Service by mail or phone for instructions on
how to pack and ship the product to Maverick's National Service Center
located as follows:
Maverick Customer Service
94 Mayfield Ave.
Edison NJ 08837
Telephone: (732) 417-9666
Hours: Weekdays 8:30 AM- 4:30 PM
Do not send any parts or product to Maverick without calling and
obtaining a Return Authorization Number and instructions.
This warranty is VOID if instructions for use are not followed; for accidental
damage; for commercial use; for damage incurred while in transit; or if the
scale has been tampered with.
This warranty gives you specific legal rights and you may also have other
rights which vary from state to state.
www.maverickhousewares.com
MANUFACTURER’S
CERTIFICATE OF CALIBRATION
This is to certify that instrument referenced
below fully meets the manufacturer’s
published specifications and that calibration
was accomplished using genarally accepted
standards which are traceable to NIST.
Date of calibration : ________________________
Model Number:
PT-100
Instrument Serial # : _______________________
Reference Instrument: _____________________
Ambient Temperature: 73°F +/- 9°F
Test Temperature
+32 °F (C) _________°F
+212 °F (100°C) _________°F
PLEASE NOTE: Performing recalibration voids all warranties
regarding calibration and traceability to NIST.
Maverick assumes no responsibility for the accuracy of
products calibrated by the customer.
Test Temperature Probe Reading
Ambient Humidity: 50% +/- 10%
Pro Temp
85-638-D02
85-638-D02 bk85-638-D02 ft