The installation must conform with local codes or, in
absence of local codes, the National Gas and Propane
Installation Code CSA B149.1 in Canada, or the National
Fuel Gas Code, ANSI Z223.1 / NFPA 54 in the United
States. Suitable for mobile home installation if installed
in accordance with the current standard CAN/CSA
Z240MH Series, for gas equipped mobile homes, in
Canada or ANSI Z223.1 and NFPA 54 in the United
States.
A
s long as the required clearance to combustibles is
maintained, the most desirable and benefi cial location for an appliance is in the center of a building, thereby
allowing the most effi cient use of the heat created. The location of windows, doors and the traffi c fl ow in the
room where the appliance is to be located should be considered. If possible, you should choose a location
where the vent will pass through the house without cutting a fl oor or roof joist.
If the appliance is installed directly on carpeting, vinyl tile or other combustible material other than wood
ooring, the appliance shall be installed on a metal or wood panel extending the full width and depth.
Some appliances have optional fans or blowers. If an optional fan or blower is installed, the junction box must
be electrically connected and grounded in accordance with local codes, use the current CSA C22.1 Canadian
Electrical Code in Canada or the ANSI/NFPA 70 National Electrical code in the United States.
We suggest that our gas
hearth products be installed
and serviced by professionals
who are certied in the U.S.
by the National Fireplace
Institute
®
(NFI) as NFI Gas
Specialists
www.ncertied.org
2.3 GENERAL INFORMATION
FOR YOUR SATISFACTION, THIS APPLIANCE HAS BEEN TEST-FIRED TO ASSURE ITS OPERATION AND
QUALITY!
RATES AND EFFCIENCES
NG P
Altitude (FT) 0-4,500 0-4500
Max. Input (BTU/HR) 17,000 17,000
Max. Output Steady State (BTU/HR) 10,900 10,900
Effi ciency (w/the fan on) 64% 64%
A.F.U.E. (Annual Fuel Utilization Effi ciency) 53% 53%
Min. Inlet Gas Supply Pressure 4.5" (11mb) w.c. 11" (27mb) w.c.
Max. Inlet Gas Supply Pressure 7" (17mb) w.c. 13" (32mb) w.c.
Manifold Pressure (Under Flow Conditions) 3.5" (9mb) w.c. 10" (25mb) w.c.
MODEL DESIGNATIONS
FUEL TYPE OPERATING SYSTEM
BGD36CFNTR
NATURAL MILLIVOLT
BGD36CFNTRE
NATURAL ELECTRONIC IGNITION
BGD36CFPTR
PROPANE MILLIVOLT
BGD36CFPTRE
PROPANE ELECTRONIC IGNITION