38
W415-1345 / C / 02.14.17
EN
To open the door, release the top and bottom door latches, located at the right side
of the door. NOTE: These door latches make up the spring relief system for the
appliance. Ensure they open freely and close sealed.
Reverse these steps to re-install the safety screen and door. Ensure safety screen is
installed correctly.
!
WARNING
GLASS MAY BE HOT, DO NOT TOUCH GLASS UNTIL COOLED.
IF EQUIPPED WITH DOOR LATCHES THAT ARE PART OF A SAFETY RELIEF SYSTEM, THEY MUST BE
PROPERLY ENGAGED. DO NOT OPERATE THE APPLIANCE WITH LATCHES DISENGAGED.
FACING AND/OR FINISHING MATERIALS MUST NOT INTERFERE WITH AIR FLOW THROUGH AIR
OPENINGS, LOUVRE OPENINGS, OPERATION OF LOUVRES OR DOORS OR ACCESS FOR
SERVICE. OBSERVE ALL CLEARANCES WHEN APPLYING COMBUSTIBLE MATERIALS.
BEFORE DOOR IS REMOVED TURN THE APPLIANCE OFF AND WAIT UNTIL APPLIANCE IS COOL TO
THE TOUCH. DOORS ARE HEAVY AND FRAGILE SO HANDLE WITH CARE.
75.1A
A barrier designed to reduce the risk of burns from the hot viewing
glass is provided with the appliance and must be installed.
Before the glass door can be removed, the safety screen must be removed.
Release the screen from the magnetic catch by pushing in at the bottom
corners of the safety screen.
SAFETY SCREEN
!
WARNING
RISK OF FIRE, MAINTAIN ALL SPECIFIED AIR SPACE CLEARANCES TO COMBUSTIBLES. FAILURE
TO COMPLY WITH THESE INSTRUCTIONS MAY CAUSE A FIRE OR CAUSE THE APPLIANCE TO
OVERHEAT. ENSURE ALL CLEARANCES (I.E. BACK, SIDE, TOP, VENT, MANTEL, FRONT, ETC.) ARE
CLEARLY MAINTAINED.
WHEN USING PAINT OR LACQUER TO FINISH THE MANTEL, THE PAINT OR LACQUER MUST BE
HEAT RESISTANT TO PREVENT DISCOLOURATION.
73.1
TOP OF FRONT
OPENING
8" (20.3cm) MANTLE
6" (15.2cm) MANTLE
4" (10.2cm) MANTLE
2" (5.1cm) MANTLE
12"
(30.5cm)
18"
(45.7cm)
16"
(40.6cm)
14"
(35.6cm)
0
$
1
7
/
(
+
(
,
*
+
7
2 4 6 8 10 12
MANTLE DEPTH (")
12
14
16
18
20
22
(")
Combustible mantel clearance can vary according to the mantel depth.
Use the graph to help evaluate the clearance needed.
6.7 MINIMUM MANTEL CLEARANCES
7.0 FINISHING
7.1 SAFETY SCREEN & DOOR INSTALLATION / REMOVAL
Loading ...
Loading ...
Loading ...