3. Sanitizing Solution
Dilute 1.5 . oz. (44 ml or 3 tbs) of a 5.25% sodium hypochlorite solution (chlorine bleach)
with 3 gal. (11.4 l) of warm water. This is a minimum amount. Make more solution if
necessary. IMPORTANT! For safety and maximum effectiveness, use the solution
immediately after dilution.
4. Sanitizing Procedure - Initial
1) Make sure the power switch is in the "OFF" position, the appliance is unplugged, and
the water supply line shut-off valve is closed.
2) Pour the sanitizing solution over the extruding head until the evaporator assembly and
the reservoir are full and the solution starts to overow into the drain pan. Allow to soak
for 10 minutes.
3) Scrub the inside of the ice storage bin, inside of the bin top, the agitator, drip ring,
ice chute area, spout A, spout B, grille, and the inside of the drain pan using a nylon
scouring pad, brushes, and sanitizing solution. Rinse all parts thoroughly with clean
water. NOTICE! Be sure to keep the switch mounted on the bin top dry.
4) Move the control switch to the "ICE" position. Replace the air lter, louver, drip ring,
agitator, bin top, grille, spout A, spout B, and panels in their correct positions.
5) Plug the appliance into the electrical outlet. Move the power switch to the "ON" position.
Make ice using the solution until the appliance stops making ice.
6) Move the power switch to the "OFF" position, then unplug the appliance from the
electrical outlet.
7) Remove the front panel, top panel, and bin top.
8) Pour clean, warm water into the ice storage bin and melt any remaining ice.
9) Remove the louver and air lter. Plug the appliance into the electrical outlet. Move the
control switch to the "DRAIN" position, then move the power switch to the "ON" position.
Allow the water system to drain completely.
10) Move the power switch to the "OFF" position, then unplug the appliance from the
electrical outlet.
5. Sanitizing Procedure - Final
1) Make sure the power switch is in the "OFF" position, the appliance is unplugged, and
the water supply line shut-off valve is closed.
2) Remove the agitator. Pour the sanitizing solution over the extruding head until the
evaporator assembly and the reservoir are full and the solution starts to overow into
the drain pan. Allow to soak for 10 minutes.
3) Move the control switch to the "ICE" position. Replace the air lter, louver, agitator, bin
top, and panels in their correct positions.
4) Plug the appliance into the electrical outlet. Move the power switch to the "ON" position.
Make ice using the solution until the appliance stops making ice.
5) Move the power switch to the "OFF" position, then remove the louver and air lter. Move
the control switch to the "DRAIN" position, then move the power switch to the "ON"
position. Allow the water system to drain completely.