4.3 Directions of how to design a housing for the fireplace
Enclosure must be stable and be constructed of non-combustible materials.
Enclosure and fire must be installed above ground level and have adequate drainage.
The enclosure must have a ventilation slot with open area of minimum 150cm2.
Ventilation allows for residual heat and unburnt gases to escape the enclosure.
Gas fire pits must be assessed and certified to AS 5263.0 Gas appliances and the below additional requirements.
Gas fire pits must be constructed such that the burner is at a minimum height of 0.7m above the ground.
A gas fire pit with a burner less than 1m above the ground must be guarded to the full height of the flame such
that a child aged between 2 and 6 years of age cannot gain access to the flame when assessed in accordance
with IEC Guide 117.
A guard incorporated into an appliance to comply with requirement 2 (above) must be an integral part of the
appliance.
All necessary information concerning the touchable surfaces of the equipment, including the following, shall be
gathered:
Classification of surface temperatures as hot, moderate or cold
Material and texture of the surface
All normal operating conditions of the equipment including the setting that results in maximum temperatures
of the touchable surfaces
The probability of contact, taking into account the arm’s reach of a person shown in below Figure and Table
Age (Years)
Arm’s reach in the vertical direction
(see (a) of Figure measured from the floor (m)
Children from 2 years to less than 6 years 1,5