Napoleon IR3GNSB Infrared Series Direct Vent Natural Gas Fireplace

User Manual - Page 6

For IR3GNSB.

PDF File Manual, 76 pages, Read Online | Download pdf file

IR3GNSB photo
Loading ...
Loading ...
Loading ...
6
W415-1355 / A / 11.16.16
EN
2.4 GENERAL INFORMATION
The installation must conform with local codes or, in
absence of local codes, the National Gas and Propane
Installation Code CSA B149.1 in Canada, or the National
Fuel Gas Code, ANSI Z223.1 / NFPA 54 in the United
States. Suitable for mobile home installation if installed
in accordance with the current standard CAN/CSA
Z240MH Series, for gas equipped mobile homes, in
Canada or ANSI Z223.1 and NFPA 54 in the United
States.
We suggest that our gas
hearth products be installed
and serviced by professionals
who are certied in the U.S.
by the National Fireplace
Institute
®
(NFI) as NFI Gas
Specialists
www.ncertied.org
4.1C
Some appliances have optional fans or blowers. If an optional fan or blower is installed, the junction box must
be electrically connected and grounded in accordance with local codes, use the current CSA C22.1 Canadian
Electrical Code in Canada or the ANSI/NFPA 70 National Electrical code in the United States.
FOR YOUR SATISFACTION, THIS APPLIANCE HAS BEEN TEST-FIRED TO ASSURE ITS OPERATION AND
QUALITY!
IR3G
NG P
Altitude (FT) 0-4,500 0-4,500
Max. Input (BTU/HR) 24,000 24,000
Max. Output (BTU/HR) 19,200 19,200
Effi ciency (w/the fan on) 80% 80%
A.F.U.E. (maximum value) 77% 77%
Min. Inlet Gas Supply Pressure 4.5" (11mb) Water
Column
11" (27mb) Water Column
Max. Inlet Gas Supply Pressure 13" (32mb) Water
Column
13" (32mb) Water Column
Manifold Pressure (Under Flow Conditions) 3.5" (9mb) Water
Column
10" (25mb) Water Column
When the appliance is installed at elevations above 4,500ft (1371m), and in the absence of specifi c
recommendations from the local authority having jurisdiction, the certifi ed high altitude input rating shall be
reduced at the rate of 4% for each additional 1,000ft (305m). Expansion / contraction noises during heating
up and cooling down cycles are normal and to be expected.
This appliance is not approved for closet or recessed installations. It is approved for bathroom, bedroom
and bed-sitting room installations and is suitable for mobile homes. The natural gas model is suitable for
installation in a mobile home that is permanently positioned on its site and fuelled with natural gas.
A barrier designed to reduce the risk of burns from the hot viewing glass is provided with the
appliance and must be installed.
64.2%
IR3G
Loading ...
Loading ...
Loading ...