25
W415-1355 / A / 11.16.16
EN
!
WARNING
DO NOT USE SUBSTITUTE MATERIALS.
GLASS MAY BE HOT, DO NOT TOUCH GLASS UNTIL COOLED.
CARE MUST BE TAKEN WHEN REMOVING AND DISPOSING OF ANY BROKEN DOOR GLASS OR
DAMAGED COMPONENTS. BE SURE TO VACUUM UP ANY BROKEN GLASS FROM INSIDE THE
APPLIANCE BEFORE OPERATION.
DO NOT STRIKE, SLAM OR SCRATCH GLASS. DO NOT OPERATE APPLIANCE WITH GLASS
REMOVED, CRACKED, BROKEN OR SCRATCHED.
56.1C
Replacement glass/frame assembly shall be replaced as a complete unit as supplied by the
appliance manufacturer.
Secure the media tray to the burner using 6 screws (W570-0001).
When removing the media tray make sure the glass media
is away from the center of the screen, exposing the burner,
remove screws and lift media tray out.
When replacing burner, absolutely no glass media can be
surrounding the orifi ce. HINT: If glass surrounds the orifi ce,
insert a clean bag into a vacuum cleaner and vacuum out
glass media. Replacement glass media can be ordered from
Wolf Steel Ltd.
8.4 DOOR GLASS REPLACEMENT
8.5 MEDIA TRAY INSTALLATION
8.6 FCM REPLACEMENT
TURN OFF THE GAS AND ELECTRICAL POWER BEFORE SERVICING THE APPLIANCE.
THE APPLIANCE MAY BE HOT. DO NOT SERVICE APPLIANCE UNTIL IT HAS COOLED.
!
WARNING
ACCESS PLATE
A. To access the Fan Control Module, you must fi rst pull out
the appliance, to provide enough room to access the left
access plate.
B. Remove the screws holding the access plate in position.
C. Unplug the Fan Control Module from the junction box.
Unplug the night light plug and blower plug (if applicable)
from the Fan Control Module.
NOTE: Ensure that the ON/OFF switch is in the ON ( - )
position.
D. Remove the 2 screws securing the Fan Control Module
the access plate and replace.
E. Reinstall the plugs and access plate