Perlick HP48RTS62R3

User Manual - Page 31

For HP48RTS62R3.

PDF File Manual, 38 pages, Read Online | Download pdf file

HP48RTS62R3 photo
Loading ...
Loading ...
Loading ...
31
Operation & Installation Manual
Signature Series Beer Dispensers (HP15, HP24 and HP48 models)
CONNECTING THE REGULATOR TO THE CO2
CYLINDER
1. Remove the blue plug from the regulator tting. NOTE: Do
not remove the carbonic washer.
2. Screw regulator onto gas cylinder valve. Tighten with wrench
until vertically straight. Be sure that shut-o valve on regula-
tor is in the OFF (horizontal) position.
3. Place screw clamp over the end of red line and push onto
regulator tailpiece. Tighten clamp with a screwdriver.
4. Turn regulator adjusting screw counterclockwise until it turns
freely.
5. Turn hand valve counterclockwise on the CO2 cylinder to the
fully open position.
6. Turn regulator adjusting screw clockwise until desired pres-
sure is reached (approximately 12-15 lbs.) Tighten stop nut on
adjusting screw.
7. Open shut-out valve on bottom of regulator.
CO2 LEAK TEST
Dilute a small amount of liquid dishwashing soap and rub the
soapy mixture around each connection. If bubbles appear,
tighten connection.
REPLACING THE CO2 GAS CYLINDER
1. Turn CO2 hand valve clockwise until seated and close shut-
o valve on regulator.
2. Unscrew regulator from cylinder tting.
3. Replace carbonic washer (Part No. 157F2P), if needed, and
reattach regulator to lled cylinder.
4. Turn CO2 hand valve counterclockwise until fully open. Turn
regulator shut- valve to open position.
5. Adjust CO2 gas ow as required, turning clockwise for higher
pressure.
CAUTION
Do not use keg coupler as a handle to lift keg.
PROPER CO2 HANDLING
ALWAYS...
Connect a regulator (reducing valve) to CO2 cylinder.
Secure cylinder in upright position whether in storage or in
use.
Keep cylinder away from heat. Rupture disc vents at 122°F
maximum.
Ventilate room after gas leakage.
Check the last DOT test date on cylinder neck before lling.
If more than ve years old, the cylinder must be retested to
DOT specications.
Be sure CO2 cylinder outlet tting is free of dust or dirt before
attaching regulator.
Store CO2 cylinder and regulator assembly upright.
Allow only properly trained and experienced personnel to
handle high pressure gas.
NEVER...
Connect cylinder directly to a keg without a regulator (reduc-
ing valve)
Drop or throw regulator or CO2 cylinder.
Transport CO2 cylinder in a closed vehicle.
Apply oil to a regulator.
Shut o CO2 cylinder when not in use. You will not save gas
by doing so!
Allow untrained, inexperienced personnel to handle high
pressure gas.
CAUTION
Be sure to close the gas shut-o valve when untapping the keg.