Napoleon HDX35NT STARfire Series Direct Vent Natural Gas Fireplace

User Manual - Page 46

For HDX35NT.

PDF File Manual, 128 pages, Read Online | Download pdf file

HDX35NT photo
Loading ...
Loading ...
Loading ...
46
W415-1434 / 06.09.15
EN
HDX35
NG 1/4" (0.6mm) GLASS 1/4" (0.6mm) LOGS
LP 3/4" (1.9mm) GLASS 1/2" (1.3mm) LOGS
It’s important to periodically perform a visual check of the pilot and burner ames. Compare them to the
illustration provided. If any ames appear abnormal call a service person.
FLAME MUST ENVELOP
UPPER 3/8” (9.5mm) TO 1/2”
(12.7mm) OF FLAME SENSO
R
PILOT
BURNER
ELECTRODE
FLAME
SENSOR
3/8” - 1/2”
(9.5mm - 12.7mm)
54.1B
MAXIMUM INPUT RATE
NG 35,000 BTU/HR
LP 35,000 BTU/HR
9.3 VENTURI ADJUSTMENT
This appliance has an air shutter that has been factory set open according to the chart below:
Regardless of venturi orientation, closing the air shutter will cause a more yellow ame, but can lead to carbon-
ing. Opening the air shutter will cause a more blue ame, but can cause ame lifting from the burner ports. The
ame may not appear yellow immediately; allow 15 to 30 minutes for the nal ame colour to be established.
AIR SHUTTER ADJUSTMENT MUST ONLY BE DONE BY A QUALIFIED INSTALLER!
49.1
9.4 FLAME CHARACTERISTICS
Loading ...
Loading ...
Loading ...