Sunstone SUNCHSZ30IRNG 30 Inch Stainless Steel Built-In Grill

User Manual - Page 12

For SUNCHSZ30IRNG.

PDF File Manual, 30 pages, Read Online | Download pdf file

SUNCHSZ30IRNG photo
Loading ...
Loading ...
Loading ...
Minimum Distances to Combustible Materials or other
Appliance ONLY, Non-Combustible materials do not apply!
(A) Must use vent hood above grill for enclosed structures
(B) Minimum clearance from floor to overhead structure 8’ Min. Clearance
(C) Minimum distance from counter to overhead structure 5’ Min. Clearance
(D) Minimum clearance from all combustible materials 24” Min. Clearance
(E) Must have TWO Vents in HIGH position for Natural Gas
(F) Must have TWO Vents in LOW position for Liquid Propane
(G) Install Non-Combustible Barrier Shielding, Stainless Steel Sheet is recommended.
(H) Island Structure must be Non-Combustible otherwise must use grill jacket or metal cabinet.
BODILY INJURY: Failure to maintain required clearances create a fire hazard that
may result in property damage or serious personal injury.
Clearances to Combustible Construction:
Minimum of 24” from the sides and rear of grill must be maintained to adjacent vertical combustible
construction above the countertop level. You should take in account that there is a large volume of heat,
and smoke will exhaust from the rear of the grill. This may discolor or damage unprotected areas, do not
install under unprotected combustible construction without using a fire safe ventilation system. A 24”
minimum clearance must be maintained under the countertop to combustible construction. The clearance
can be modified by a use of an insulated jacket.
DEFINITION OF COMBUSTIBLE MATERIAL -
Any
materials of a building structure or decorative structure
made of wood, compressed paper, plant fibers, vinyl/plastic or other materials that are capable of transferring heat
or being ignited and burned. Such material shall be considered combustible even though flame-proofed, fire-
retardant treated or surface-painted, or plastered.
GRILL INSTALLATION
ENCLOSED INSTALLATION
Minimum Distances to Combustible Materials or other
Appliance ONLY, Non-Combustible materials do not apply!
(A) From Floor to Overhead Combustible Structure 8’ Min. Clearance
(B) From Counter to Overhead Combustible Structure 5’ Min. Clearance
(C) From Appliance to Combustible Material 24” Min. Width Clearance
(D) From Counter to Combustible Material if within 24” of Appliance
24
" Min.
Height
Clearance
(E) Must have TWO Vents in HIGH position for Natural Gas
(F) Must have TWO Vents in LOW position for Liquid Propane
PAGE 8
The Tab
le below refers to illustration on page 7
The Table below refers to illustration on page 9