Step !
Preparing for Installation
Positioning the cooktop
The cooktop is designed to look best when centered
in a cabinet its same width.
The exhaust vent beneath the cooktop must be
located between wall studs or floor joists so that
ductwork may be installed properly.
At least 6" must be allowed between side edges
of cooktop and adjacent walls.
1/2" Flat area
for support
6" Min. to
side wall
Avoid placing cabinets above the cooktop unit,
if possible, in order to reduce the hazards
caused by reaching over heated surface units. If
cabinets are placed over the cooMop, the risks
can be reduced by installing a range hood that
projects horizontally a minimum of 5" beyond
the bottom of the cabinets.
If cabinetry is used above cooktop, allow a
minimum 30, clearance between the cooking
surface and the bottom of any unprotected cabinet.
If clearance between cooktop and cabinetry is
less than 30,, cabinet bottom must be protected
with flame retardant millboard at least 1/4"
thick, covered with 28 gauge sheet steel or
0.020' thick copper. Clearance between cooMop
and protected cabinetry must NEVER BE LESS
THAN 24".
EXCEPTION: Installation of a listed microwave
oven or cooking appliance over the cooktop
shall conform to the installation instructions
packed with that appliance.
A 15" minimum must be kept from the side
edge of cooMop to the bottom of any cabinet not
directly above cooMop. If clearance is less than
15% adjacent cabinets should be at least 6" from
side edge of cooktop.
Step2
Preparing the Base Cabinet
This co&top is designed to fit easily into a variety of
cabinets. Howeveg some cabinets may require
modifications.
Preparing a cabinet that is against a wall
In some cabinets, the sides may need to be scooped
or cut down 2" as shown, and the corner braces
removed in order to accommodate the unit.
In 75 cm and 90 cm frameless European cabinets,
the back panel may need to be cut down 5" to
accommodate the unit.
Preparing a peninsula or island type cabinet
Ina peninsula or island type cabinet, the sides may
need to be scooped or cut down, and the corner
braces removed in order to accommodate the unit.
5" Approx.
for European
cabinets
2"
Approx.
Step3
Rough Preparation of Junction Box
IMPORTANT--FOR PERSONAL SAFETY,
REMOVE HOUSE FUSE OR OPEN
CIRCUIT BREAKER BEFORE PREPARING
JUNCTION BOX.
Install an approved junction box within shaded
area shown in diagram. Junction box must be at
least 101/2"below top of cabinet.
Run conductors from residence wiring to
junction box according to local electrical codes.
16'*