6. Check the electrical connections on the indoor unit.
Route of Pipeline
Depending on the position of the unit, the piping may be routed
sideway from the left or the right (Fig. 1), or vertically from the back
(Fig. 2) (depending on the pipe length of the indoor unit). The indoor
unit will draw it’s power from the exterior unit. In the case of sideway
routing, cut off the outlet cutting stock of the opposite side.
WARNING - All exterior wiring must be in LFNC-B or equivalent in
accordance with NEC requirements.
Fig. 1
Fig. 2
Refrigerant pipe
Drain Hose and
Cables
Refrigerant pipe
Drain Hose and
Cables
Outlet material preparation
INSTALLATION INSTRUCTIONS
WARNING - All interior wiring must be compliant articles
200-300 of NEC.