P32D3240 Southbend

User Manual - Page 5

For P32D3240.

PDF File Manual, 40 pages, Read Online | Download pdf file

P32D3240 photo
Loading ...
Loading ...
Loading ...
OWNER’S MANUAL 1199797 REV 0 (6/14)
PAGE
5
OF 40
RADIANT BROILER
SPECIFICATIONS
NOTICE
Local codes regarding installation vary greatly from one area to another. The National Fire Protection Association, Inc.
states in its NFPA 96 latest edition that local codes are the “authority having jurisdiction” when it comes to installation
requirements for equipment. Therefore, installations should comply with all local codes.
Southbend reserves the right to change specications and product design without notice. Such revisions do not entitle
the buyer to corresponding changes, additions, or replacements for previously purchased equipment.
This product is intended for commercial use only, not for household use.
The installation must conform with local codes, or in the absence of local codes, with the National Fuel Gas Code,
ANSI Z223.1, Natural Gas Installation Code, CAN/CGA-B149.1, or the Propane Installation Code CAN/CGA-B149.2,
as applicable, including:
1. The appliance and its individual shutoff valve must be disconnected from the gas supply piping system during any
pressure testing of that system at test pressures in excess of 1/2 psi (3.45 kPa).
2. The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve `
during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psi (3.45
kPa).
Minimum clearance from combustible surfaces is 6” on the sides and back. Minimum clearance from non-combustible
surfaces is 0” on the sides and back.
Adequate clearance must be provided in the aisle in front of the broiler to permit operation (including pulling out of
broiler racks and removal of the drippings drawers), as well as for servicing. No additional clearance is required for
servicing as the broiler is serviceable from the front.
The high-temperature ue products ow out through the top of the broiler. Installation under a vented hood is
recommended.
Units have 6” legs or casters, and may be installed on combustible oors.
WARNING
MINIMUM CLEARANCES FROM COMBUSTIBLE CONSTRUCTION
SPECIFICATIONS
CLEARANCES
WARNING
Improper ventilation can result in personal injury or death. Ventilation which fails to properly remove ue products can
cause headaches, drowsiness, nausea, or could result in death.
All units must be installed in such a manner that the ow of combustion and ventilation air is not obstructed. Provisions
for adequate air supply must be provided. Do not obstruct the front of the unit at the bottom where the air lter is
located or below the oven door as combustion air enters at these locations.
VENTILATION
Loading ...
Loading ...
Loading ...