I. Remove regulator cover screw on top of gas valve, and insert an appropriate
screwdriver into adjustment screw.
II. Turn adjustment screw clockwise to increase input rate, or counter clockwise to
decrease input rate.
III. Replace cover screw, or cover hole temporarily with your finger to check new
manifold pressure setting. Do not set manifold pressure lower than 2.0 inches w.c.
or higher than 3.0 inches w.c. when adjusting input rate.
IV. Measure new input rate (cover screw must be installed). Repeat steps I.-IV. until
the input rate is within +/-2% of the nameplate input rating.
V. If the actual input rate can not be set to within 2 % of the correct input rating by
adjusting manifold pressure, a change in gas orifice size is required. Consult the
boiler manufacturer for information on correct orifice sizing. The specific gravity
(G) and the higher heating value (HHV) of the local natural gas must be obtained
from the local gas utility in order to determine the proper orifice size.
f. After adjusting input rate, turn boiler off, remove manometer or pressure gauge, reinstall
1/8" plug on gas valve. Turn boiler on.
Restore all gas appliances that may have been shut off (while measuring boiler input rate) to
normal operating conditions.
J. SET THERMOSTAT TO DESIRED ROOM TEMPERATURE
Observe several operating cycles to verify proper operation.
I_ REVIEW ALL INSTRUCTIONS
Review all instructions shipped with this boiler with owner or maintenance person. Instructions
must be affixed on or adjacent to the boiler.
L. COMPLETE AND SIGN THE INSTALLATION AND CHECK-OUT CERTIFICATE ON THE
FOLLOWING PAGE.