Weil-McLain SGO SERIES 4 OIL-FIRED STEAM BOILER SGO-7 Residential Boilers

User Manual - Page 36

For SGO SERIES 4 OIL-FIRED STEAM BOILER SGO-7.

PDF File Manual, 48 pages, Read Online | Download pdf file

SGO SERIES 4 OIL-FIRED STEAM BOILER SGO-7 photo
Loading ...
Loading ...
Loading ...
Part number 550-142-330/0421
36
SGO
OIL-FIRED NATURAL DRAFT STEAM BOILER — SERIES 4 — Boiler Manual
SERVICE฀TECHNICIAN฀ONLY฀—฀read฀and฀follow฀completely.
Annual service check list
Annual Service Call
Checklist
(follow in order listed below)
Dates Comments
1
Check that boiler area is free from
combustible materials, gasoline and
other flammable vapors and liquids.
2
Check for and remove any obstruction
to combustion and ventilation air flow
to boiler.
3
Check breeching and chimney or vent
for obstructions, damage, etc. Repair
or replace as necessary.
4
Clean boiler ue ways. See page38.
5
Perform service on low water cuto,
relief valve and gauge glass. See
page37.
6
Check boiler and piping for leaks and
repair if found.
7
Inspect and adjust burner. See burner
manual and:
•change nozzle.
•check ignition electrode settings.
•clean blower housing and wheel.
•make sure blower wheel turns
freely.
•oil burner motor if required.
•clean air inlet.
•clean or change fuel lter and
strainer.
8
Make sure boiler is lled with water.
See page34
.
9
Start unit and verify combustion
settings with combustion test
equipment. See page34.
10
Verify operation of all controls on
boiler. See page34.
Any parts of the boiler furnished by Weil-McLain must be replaced by parts listed in
Weil-McLain Boiler and Repair Parts Book.
Loading ...
Loading ...
Loading ...