ThismanualcontainsimportantCareandUseinformation
forallThermadorProfessional®Ranges.Whenusingthis
manual,itiscriticalthatyouknowthemodelnumberof
yourrange,assomeinformationwillbeuniqueto each
range.Themodelnumbermaybefoundontheratingplate
locatedontherangeasidentifiedonpage38ofthis
manual.Thechartsonthefollowingpagessummarizethe
variousrangemodelsandidentifythefeaturesof each
range
Safety
IMPORTANT SAFETY INSTRUCTIONS
--_ READ AND SAVE THESE INSTRUCTIONS
Gas and Electrical Requirements and
Grounding Instructions
PLEASE READ CAREFULLY
30" Dual-Fuel Models:
240/208 volts, 60 Hz., 35 Amp electrical circuit required for
each line.
36" Dual-Fuel Models:
240/208 volts, 60 Hz., 35 Amp electrical circuit required for
each line.
48" Dual-Fuel Models:
240/208 volts, 60 Hz., 50 Amp electrical circuit required for
each line.
WARNING:
ALWAYS DISCONNECT TH E ELECTRICAL
PLUG FROM THE WALL RECEPTACLE
BEFORE SERVICING THIS UNIT
It is recommended that a dedicated circuit servicing this
appliance be provided.
The use of gas cooking appliances results in the production
of heat and moisture.
CAUTION:
FOR PERSONAL SAFETY, THIS APPLIANCE
MUST BE CONNECTED TO A PROPERLY
GROUNDED AND POLARIZED ELECTRICAL
POWER SUPPLY.
WARNING:
To avoid possible burn or fire hazard, a
backguard designed specifically for this range
must be installed whenever the range is used.
See Installation Instructions for electrical requirements and
grounding instructions.
It is the personal responsibility and obligation of you, the
user, to have this appliance connected to the electrical
power supply by a qualified electrician, in accordance with
the National Electrical Code and/or applicable local codes
and ordinances.
_ CAUTION m ALL MODELS:
IN CASE OF AN ELECTRICAL FAILURE
If for any reason a gas control knob is turned ON
and there is no electrical power to operate the
electronic igniters on the range's cooktop
burners, turn OFF the gas control knob and wait
5 minutes for the gas to dissipate before lighting
the burner manually.
To light the burners manually, carefully hold a
lighted match to the burner ports and turn the
gas control knob to LV_. During a power failure,
you can use the standard cooktop burners, but
each must be lit with a match.
DO NOT attempt to light the two left burners
manually. These burners are equipped with the
ExtraLow ® feature and cannot be lit manually.