troubleshooting
GDS60-1 ONLY
GDS60-1 ONLY
symptom problem test solution
Pilot lights
Stops sparking / pilot
remains lit but burner
will not turn on.
Wiring / connection. - Inspect all wires, ensure good tight connections. Verify that all wiring
is installed exactly as specifi ed.
Wiring harness. - Inspect the wiring harness and verify the harness is tightly connected
to the module. Verify that all wires are connected in the right order.
see "wiring diagram" section.
Exhaust fumes smelled
in room, headaches.
Appliance is spilling
Check all seals.
Check if exhaust is re-entering through an open door or window.
White / grey fi lm forms. Sulphur from fuel is being depos-
ited on glass, logs or combus-
tion chamber surfaces.
- Clean the glass, see "care of glass" section.
- DO NOT CLEAN GLASS WHEN HOT.
- If deposits are not cleaned off regularly, the glass may become
permanenttly marked.
Flames are very ag-
gressive
Door is ajar. - Tighten door clamps (if applicable).
Venting action is too great. - Restrict vent exit with restrictor plate. See "restricting vents" section
(if applicable).
Main burner fl ame is a
blue, lazy, transparent
ame.
Blockage in vent. - Remove blockage. In extreme conditions, ice buildup may occur
on the terminal and should be removed. To minimize this from
happening again, it is recommended that the vent lengths that pass
through unheated spaces (attics, garages, crawl spaces) should
be wrapped with an insulated mylar sleeve. Prevent sleeve from
sagging. Contact your local authorized dealer for more information.
Compromised venting. - Check venting system parameters (seal, length, rise, etc.).
Main burner goes out;
pilot goes out.
Vent recirculation. - Check joint seals and installation.
Main burner and pilot
cycles on and off.
GS60-1 ONLY
Venting is spilling. - Test with spill switch bypassed. Replace if defective.
- Check for vent blockage.
Loading ...
Loading ...