direct venting - model GDS60-1
2.4 venting application fl ow chart
Top Exit
Horizontal Termination
Vertical rise is equal
to or greater than the
horizontal run
Vertical rise is equal
to or greater than the
horizontal run
Vertical rise is less
than horizontal run
Vertical rise is less
than horizontal run
Horizontal run +
vertical rise to
maximum of
24.75 feet (7.5m)
Horizontal run +
vertical rise to
maximum of
19 (5.8m)
4.2 times the vertical
rise equal to or
greater than the
horizontal run
3 times the vertical
rise equal to or
greater than the
horizontal run
Horizontal run +
vertical rise to
maximum of
40 feet (12.2m)
Horizontal run +
vertical rise to
maximum of
40 feet (12.2m)
Vertical Termination
REAR EXIT
Horizontal Termination
Vertical Termination
Vertical rise is equal
to or greater than
the horizontal run
Vertical rise is less
than horizontal run
Vertical rise is equal
to or greater than
the horizontal run
Vertical rise is less
than horizontal run
3.5 times the
vertical rise equal to
or greater than the
horizontal run
3 times the vertical
rise equal to or
greater than the
horizontal run
Horizontal run +
vertical rise to
maximum of
40 feet (12m)
Horizontal run +
vertical rise to
maximum of
24.75 feet (7.5m).
Horizontal run +
vertical rise to
maximum of
40 feet (12m)
Horizontal run +
vertical rise to
maximum of
40 feet (12m)