6.6 FIREBRICK INSTALLATION AND DAMPER OPERATION
OPERATION OF THE APPLIANCE WITHOUT THE FIREBRICKS CAN RESULT IN EXCESSIVE
TEMPERATURES THAT COULD DAMAGE THE APPLIANCE, CHIMNEY AND THE
SURROUNDING ENCLOSURE.
NOTE: The damper must be in the "OPEN" position
when burning.
To close the damper, pull the damper control rod down and
push it to the right.
To open the damper, push the damper control rod to the left
side and release.
OPEN CLOSED
A. Tilt and install the right rear
firebrick against the wall.
B. Install the middle and left
rear firebricks.
C. Install the bottom
firebricks to aid securing
the rear firebricks against
the wall.
D. Tilt the top right firebrick
and secure under the
retaining bracket.
E. Install the remaining top firebricks,
securing under the retaining
brackets. Install the andirons into
the bottom firebricks.
NOTE: If damper becomes unthreaded it will
remaining situated in the "OPEN" position.
NOTE: Ensure fibre panels set in behind brick are in good condition before installing firebrick. If fibre panels
need to be replaced, hold panels in position or place with masking tape until fire brick is installed.
OPEN
CLOSED
OPEN
CLOSED
6.6.1 FIREBRICK INSTALLATION
6.6.2 DAMPER OPERATION