Installation
*INSTALLATION*
86
Electrical connection
Danger of injury!
Installation, repairs and other
maintenance work by unqualified
persons could be dangerous. Miele
cannot be held liable for
unauthorised work.
The appliance may only be
connected to the mains electricity
supply by a qualified electrician who
is familiar with and complies with the
national regulations and any
additional regulations of the local
electricity provider.
The appliance must be connected to an
electrical system designed in
accordance with VDE0100.
Connection to a switched socket (in
accordance with VDE0701) is
recommended as this provides easier
access in the case of a service call.
If the appliance is hardwired or if the
plug is not accessible, an additional
means of disconnection must be
provided for all poles.
Suitable means of disconnection
include switches with an all-pole
contact gap of at least 3mm. These
include circuit breakers, fuses and
contactors (EN60335).
Connection data is given on the data
plate situated at the front of the oven
compartment. Please ensure the
connection data matches the
household supply.
When contacting Miele, please quote
the following:
- Model identifier
- Serial number
- Connection data (mains voltage/
frequency/maximum rated load)
When replacing the cable supplied
with another cable or changing the
connection, only cable type
H05VV-F with a suitable cross-
sectional area (CSA) may be used.
Temporary or permanent operation on
an autonomous power supply system or
a power supply system that is not
synchronised with the mains power
supply (e.g. island networks, back-up
systems) is possible. A prerequisite for
operation is that the power supply
system complies with the specifications
of EN50160 or an equivalent standard.
The function and operation of the
protective measures provided in the
domestic electrical installation and in
this Miele product must also be
maintained in isolated operation or in
operation that is not synchronised with
the mains power supply, or these
measures must be replaced by
equivalent measures in the installation.
As described, for example, in the
current version of
BS OHSAS 18001–2 ISO 45001.
Oven
The wires in the mains lead are
coloured as follows:
Green/yellow = earth
Blue = neutral
Brown = live