STEP 10
Installing the Anti-Tip Device
-4,WARNING:
° Range must be secured with an approved
Anti-Tip device.
Unless properly installed, the range could be tipped
by you or a child standing, sitting or leaning on an
open door.
, After installing the Anti-Tip device, verify that it is
properly installed and engaged 'by opening the broiler
compartment and inspecting the rear leveling leg. Make
sure it fits securely in the slot.
This range has been designed to meet all
recognized industry tip standards for all normal
conditions.
The installation of the Anti-Tip device must meet
all local codes for securing the appliance°
The use of this device does not preclude tipping
of the range when not properly installed_
if the Anti-Tip device supplied with the range does
not fit this application, use the universal Anti-Tip
device WB2X7909o Call 1-800-4-MY-HOME®..
These Anti-Tip device installation instructions are
for wood or concrete floors and walls° Any other
type of construction may require special installation
techniques to provide adequate fastening of the
Anti-Tip device to the floor and wall.
1. Locate the device against the rear wall and either the
right or left cabinet. If the countertop overhangs the
cabinet, offset the device from the cabinet by the
amount of overhang., if there is no adjacent cabinet,
position the edge of the device at the desired location
of the range side panel
2. Use the device as
a template and mark
2 hole positions on
the wall and 2 hole
positions on the floor.
Use either the wood
or concrete floor set
of positions, depending
on your floor type°
AdjacentCabinetor
FinalLncallanof Range
SidePanel'
Legol Range
Floor
Holes
3. For wood construction, drill a 1/B"pilot hole in the
center of each of the pre-marked wood floor and wall
hole positions (a nail or awl may be used if a drill is
not available). Fasten the Anti-Tip device with the
4 screws provided.
Atlachmentto wall
For concrete construction, you will need four
V4"x 11/2"lag bolts and four _,6"ODo sleeve anchors
(not provided).. Drill the recommended size hole for
the anchors into the concrete at the center of each
pre-marked floor and wall hole position. Install the
sleeve anchors into the drilled holes and then install
the lag bolts through the device. Do not overtighten
the bolts.
4. Slide the range against the wall, and check for proper
installation by removing the broiler drawerr storage
drawer, or kick panel and inspecting the rear leveling
leg. Make sure it fits securely into the slot on the Anti-
Tip device.
WHEN ALL HOOKUPS ARE COMPLETED:
MAKE SURE ALL OF THE CONTROLS ARE LEFT
IN THE OFF POSITION,
MAKE SURE THE FLOW OF COMBUSTION
AND VENTILATION AIR TO THE RANGE IS
UNOBSTRUCTED.
Converting to LP gas
(or converting back to natural gas from LP)
This range leaves the factory set for use with natural gas.
if you want to convert to LP gas, the conversion must be
performed by a qualified LP gas installer..
The conversion instructions, sticker and LP orifices
can be found attached to the range next to the
pressure regulator..
Keep these instructions and the orifices in case you
want to convert back to natural gas_ Conversion back to
natural gas must be performed by a qualified installer.