Napoleon EPI1101M Oakdale Series Natural Vent Woodburning Fireplace

User Manual - Page 20

For EPI1101M.

PDF File Manual, 64 pages, Read Online | Download pdf file

EPI1101M photo
Loading ...
Loading ...
Loading ...
20
W415-0764 / C / 11.19.13
EN
93.1
A ash re is a small re burned quickly when you don't need much
heat. After your kindling has "caught", load at least 3 pieces of wood,
stacked loosely. Burn with the draft control fully open or closed only
slightly.
82.1
Load your larger pieces of wood compactly, packed close enough to prevent the ames from penetrating
it completely. After approximately 30 minutes, depending on the size of the load, close the draft control
completely making sure that the re is not extinguished.
DO NOT OVERFIRE THE APPLIANCE!
Over ring can occur by:
A. Burning large amounts of smaller wood pieces such as furniture scraps, skids or treated wood;
B. Vigorously burning large loads of wood with the draft control on “HIGH” (fully open) for long periods of
time (one or two hours).
C. Operating the appliance with the ash dump door blocked open or a poor gasket seal on the main door.
Has a direct ue connection been used rather than a chimney liner continuous from cap to appliance
ue collar.
83.1
A properly installed appliance should not smoke. If yours does, check the following:
Has the chimney had time to get hot?
Is the smoke passage blocked anywhere in the appliance, chimney connector or chimney?
Is the room too airtight and the air intake not connected to the outside? Try with a window partly open.
Is the smoke ow impeded by too long a horizontal pipe or too many bends?
Is it a weak draft perhaps caused by a leaky chimney, a cold outside chimney, too large a diameter of a
chimney, too short a chimney, or a chimney too close to trees or a higher roof?
6.5 LIGHTING A FIRE
6.5.1 FLASH FIRE
6.5.2 EXTENDED FIRE
6.6 SMOKING