Napoleon EPI1101M Oakdale Series Natural Vent Woodburning Fireplace

User Manual - Page 11

For EPI1101M.

PDF File Manual, 64 pages, Read Online | Download pdf file

EPI1101M photo
Loading ...
Loading ...
Loading ...
11
W415-0764 / C / 11.19.13
EN
4.0.1 TYPICAL EXISTING MASONRY
You can install your appliance using your existing masonry chimney. To do
so, follow the guidelines below. If you are using a masonry chimney, it
is important that it be built in compliance with the speci cations of the
Building Code in your region. It must normally be lined with re clay
bricks, metal or clay tiles sealed together with re cement. (Round
ues are the most ef cient).
62.2
FOLLOW MANUFACTURER’S
INSTRUCTIONS FOR
MAXIMUM LINER EXTENSION
ABOVE CHIMNEY
FLOOR
PROTECTOR
DAMPER PLATE
REMOVED OR
FASTENED IN OPEN
POSITION
SEAL WITH NON-
COMBUSTIBLE
MATERIAL
MASONRY
CHIMNEY MUST
HAVE
STRUCTURAL
INTEGRITY
LISTED
CHIMNEY
LINER
A. Remove the replace damper or fasten it permanently open.
* We recommend the following method of sealing off the damper area around the liner.
B. * Measure the throat of the replace and mark this shape on a piece of 24 gauge sheet metal ( ue
cover); cut a six-inch (6 3/4” / 171mm) hole to lie directly below the replace ue opening. Allow two
inches of material for a ange on all sides and cut to these measurements. Bend down the anges. If you
have never done this before, it might be a good idea to make a cardboard pattern and test it rst. Fasten
this ue cover in position as high as possible with two masonry screws per side through the anges into
the replace.
In Canada: Install a listed 6" (152mm) diameter exible stainless steel liner from the top of the chimney to the
insert ue collar. Attach a stainless steel liner connector or elbow to the liner and insert onto the ue collar. Fasten
with three screws. Secure the top of the liner to the chimney cap using a liner support and chimney ashing. Cap
the top of the chimney liner assembly using an approved rain cap.
In the United States: While it is not required, it is recommended that a chimney liner be installed that is continu-
ous from the insert to the top of the chimney, particularly when the insert is installed in a basement. For this type
of connection, use the “In Canada” installation instructions above.
If a continuous liner is not installed, a “direct ue connection” must be made. The direct ue connection requires a
non-combustible connector that extends from the insert into the chimney ue liner and also that the installed ue
cover be sealed below the entry point of the connector to prevent dilution of combustion products in the chimney
ue with air from inside the house. Cap the top of the chimney using an approved rain cap.
DO NOT CONNECT THIS APPLIANCE TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE. DO
NOT CONNECT TO ANY AIR DISTRIBUTION DUCT OR SYSTEM.
!
WARNING
Loading ...
Loading ...
Loading ...